Objectives: Despite its broad spectrum, conventional amphotericin B (AB) is associated with serious adverse events. Lipid-based formulations may offer safer options. We aimed to synthesize the evidence of efficacy and safety of AB formulations.
Methods: We performed a systematic review and network meta-analysis (NMA) to compare all available formulations: conventional AB; lipid complex or ABLC; colloidal dispersion or ABCD; liposomal or LAB; AB in Intralipid. Randomized controlled trials were searched in four databases. Cure, fever, chills, nephrotoxicity, death and drug discontinuation were assessed. NMA was based on Bayesian methods accounting for direct and indirect comparisons. Probability ranks estimating the best formulation were built for each outcome. The relative benefit-risk of formulations was assessed with stochastic multicriteria acceptability analyses (SMAA).
Key Findings: We identified 25 trials (n = 2996). No significant differences among drugs were observed for cure or death. All lipid-based formulations were safer than conventional AB for nephrotoxicity. AB-Intralipid was more tolerable than conventional AB and caused less chills than ABCD. AB-Intralipid was the best therapy (>60%) regarding nephrotoxicity, fever, chills and discontinuation. The scenario from SMAA favoured AB-Intralipid (81% acceptability). Conventional AB was secondary to all lipid-based formulations.
Conclusions: Amphotericin B-Intralipid was identified as safer, cost-saving treatment in comparison with other formulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jphp.12802 | DOI Listing |
Background: Liver malignancies present substantial challenges to surgeons due to the extensive hepatic resections required, frequently resulting in posthepatectomy liver failure. Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) was designed to increase the resectable liver volume, yet it is associated with significant mortality and morbidity rates. Recently, minimally invasive techniques have been incorporated into ALPPS, with the potential to improve the procedure's safety profile whilst maintaining efficacy.
View Article and Find Full Text PDFInt J Surg
January 2025
Carcinoma Department of Traditional Chinese Medicine, Dianjiang People's Hospital of Chongqing, Chongqing, PR China.
The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.
View Article and Find Full Text PDFMar Biotechnol (NY)
January 2025
Department of Aquatic Life Medicine, Pukyong National University, Busan, 48513, South Korea.
Vibriosis caused by Vibrio anguillarum has been an important bacterial disease in cultured rainbow trout (Oncorhynchus mykiss). In the present study, we evaluated the protective efficacy of a vaccine that consists of formalin-killed (FK) V. anguillarum and the alr genes knockout auxotrophic-live (AL) V.
View Article and Find Full Text PDFItal J Dermatol Venerol
January 2025
Section of Dermatology and Venereology, Department of Biomedical Sciences and Human Oncology, University of Bari, Bari, Italy -
Dig Dis Sci
January 2025
Digestive Disease Center and Research Institute, Department of Internal Medicine, SoonChunHyang University School of Medicine, Cheonan, Korea.
Background And Aim: Although long self-expandable metal stent (SEMS) with a sufficient intragastric portion is typically preferred for endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), this design can complicate endoscopic re-intervention for recurrent biliary obstruction (RBO). We evaluated the efficacy and safety of endoscopic re-intervention for RBO through the stent after EUS-HGS using a novel partially covered SEMS with an anchoring flange.
Methods: The partially covered SEMS was designed with a intrahepatic uncovered portion measuring 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!