Low-Back Pain (LBP) affects a large portion of the working population. Preventive exoskeletons have been proposed to reduce the moments on the lower back, specifically around the lumbosacral (L5/S1) joint. High correlation has been shown, between reducing the moments around the L5/S1 joint and intervertebral compression forces, which in turn have been identified as a risk factor for developing LBP. However, most passive back support exoskeletons use rigid plates or stiff beams to support the spine that limit the range of motion of the wearer. A large range of motion and versatility are especially desirable for industrial applications. To overcome these limitations, a passive biomimetic exo-spine has been designed, modelled and an initial prototype tested. Its potential to allow for a large range of motion, whilst at the same time limiting the most extreme and potentially harmful postures has been shown.

Download full-text PDF

Source
http://dx.doi.org/10.1109/ICORR.2017.8009407DOI Listing

Publication Analysis

Top Keywords

range motion
12
passive biomimetic
8
biomimetic exo-spine
8
l5/s1 joint
8
large range
8
low support
4
support passive
4
exo-spine low-back
4
low-back pain
4
pain lbp
4

Similar Publications

Hyperbaric oxygen therapy and corticosteroids as combined treatment for acute acoustic trauma.

Eur Arch Otorhinolaryngol

January 2025

Motion Sickness and Human Performance Laboratory, The Israel Naval Medical Institute, IDF Medical Corps, Haifa, Israel.

Purpose: Acute acoustic trauma (AAT) is a sudden sensorineural hearing loss (SNHL) due to exposure to high intensity impulse noise. There are no acceptable treatment guidelines, although several studies showed steroids could be effective in restoring hearing levels. A recent report suggested that steroids combined with hyperbaric oxygen therapy (HBOT) are a superior regiment for AAT.

View Article and Find Full Text PDF

This paper studies the practical prescribed-time control problem for dual-arm robots handling an object with output constraints. Firstly, by utilizing the property that the sum of internal forces in the grasping space is zero, the system model is obtained and decomposed into the contact force model and free motion model, which are orthogonal to each other. Furthermore, by combining the performance function and constraint function, the original system tracking error is transformed to a new one, whose boundedness can ensure that the original system variable converges to the predetermined range within the specified time.

View Article and Find Full Text PDF

Time Code for multifunctional 3D printhead controls.

Nat Commun

January 2025

Department of Civil and Systems Engineering, Johns Hopkins University, Baltimore, MD, USA.

Direct Ink Writing, an extrusion-based 3D printing technique, has attracted growing interest due to its ability to process a broad range of materials and integrate multifunctional printheads with features such as shape-changing nozzles, in-situ curing, material switching, and material mixing. Despite these advancements, incorporating auxiliary controls into Geometry Code (G-Code), the standard programming language for these printers, remains challenging. G-Code's line-by-line execution requires auxiliary control commands to interrupt the print path motion, causing defects in the printed structure.

View Article and Find Full Text PDF

Background: Humeral capitellar osteochondritis dissecans (OCD) lesions can be challenging to treat. Past studies have demonstrated grafting with extracellular matrix with bone marrow aspirate concentrate (ECM-BMAC) to be a viable technique for treatment of talar dome OCD, though little literature exists regarding application of this technique to the capitellum. This study aimed to report patient-reported outcomes (PROs) and return to sport (RTS) of pediatric patients at ≥1-year postoperatively who underwent ECM-BMAC grafting for capitellar OCD lesions.

View Article and Find Full Text PDF

Background: There has been an increase in both primary anatomic (aTSA) and reverse total shoulder arthroplasty (rTSA) over the last decade, with rates peaking for patients aged 75 years and older. Despite aTSA being the mainstay of treatment for patients with glenohumeral arthritis in the absence of rotator cuff insufficiency, there has been an upward trend of rTSA utilization in the elderly due to concerns about rotator cuff integrity, regardless of deformity. The purpose of this study is to evaluate outcomes including pain, function, range of motion, satisfaction, and complications in patients 80 years or older following primary anatomic and reverse total shoulder arthroplasty for osteoarthritis without full thickness rotator cuff tears.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!