Unlabelled: Many commercial cemented glenoid components claim superior fixation designs and increased survivability. However, both research and clinical studies have shown conflicting results and it is unclear whether these design variations do improve loosening rates. Part of the difficulty in investigating fixation failure is the inability to directly observe the fixation interface, a problem addressed in this study by using a novel experimental set-up. Cyclic loading-displacement tests were carried out on 60 custom-made glenoid prostheses implanted into a bone substitute. Design parameters investigated included treatment of the fixation surface of the component resulting in different levels of back-surface roughness, flat-back versus curved-back, keel versus peg and more versus less conforming implants. Visually-observed failure and ASTM-recommended rim-displacements were recorded throughout testing to investigate fixation failure and if rim displacement is an appropriate measure of loosening. Roughening the implant back (R>3µm) improved resistance to failure (P<0.005) by an order of magnitude with the rough and smooth groups failing at 8712±5584 cycles (mean±SD) and 1080±1197 cycles, respectively. All other design parameters had no statistically significant effect on the number of cycles to failure. All implants failed inferiorly and 95% (57/60) at the implant/cement interface. Rim-displacement correlated with visually observed failure. The most important effect was that of roughening the implant, which strengthened the polyethylene-cement interface. Rim-displacement can be used as an indicator of fixation failure, but the sensitivity was insufficient to capture subtle effects.

Level Of Evidence: Basic Science Study, Biomechanical Analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2017.07.008DOI Listing

Publication Analysis

Top Keywords

treatment fixation
8
fixation surface
8
fixation failure
8
fixation
5
surface improves
4
improves glenoid
4
glenoid prosthesis
4
prosthesis longevity
4
longevity vitro
4
vitro unlabelled
4

Similar Publications

Purpose: The absence of evidence based general guidelines for radiographic follow-ups of pediatric diaphyseal forearm fractures treated with ESIN results in an arbitrary array of X-ray examinations. In most pediatric traumatology departments, an X-ray check is carried out 4 weeks after ESIN osteosynthesis of forearm shaft fractures to detect incipient consolidation of the fracture. However, the elevated sensitivity to ionizing radiation requires special precautions in the pediatric populations.

View Article and Find Full Text PDF

Association Between Nail Type and Aseptic Revision Risk After Cephalomedullary Nailing for Hip Fracture.

J Bone Joint Surg Am

January 2025

Surgical Outcomes and Analysis Department, Kaiser Permanente, San Diego, California.

Background: Although the majority of intertrochanteric femoral fractures in the United States are now treated with cephalomedullary nailing, it remains uncertain whether differences in clinical performance by nail type exist. The purpose of this study was to compare the aseptic revision rates associated with the 3 most commonly utilized cephalomedullary nails in the United States today: the Gamma nail (Stryker), the INTERTAN (Smith+Nephew), and the Trochanteric Fixation Nail/Trochanteric Fixation Nail Advanced (TFN/TFNA; DePuy Synthes).

Methods: Using an integrated health-care system's hip fracture registry, patients ≥60 years of age who were treated with 1 of these 3 commonly used cephalomedullary nail devices were identified.

View Article and Find Full Text PDF

Background: In the setting of cervical open-door laminoplasty, the question of whether or not every opened laminar level should be instrumented has not been sufficiently investigated. We postulated that the surgical outcomes of open-door laminoplasty with instrumentation of every second opened level (skip-fixation) might not be inferior to those of laminoplasty with instrumentation of every opened level (all-fixation). The purpose of the present study was to test the noninferiority of laminoplasty with skip-fixation in improving myelopathy at 2 years postoperatively compared with all-fixation.

View Article and Find Full Text PDF

A decade of intracapsular cataract extraction: Clinical profile and visual outcomes at Hospital Melaka, Malaysia.

Med J Malaysia

January 2025

Universiti Sains Malaysia, School of Medical Sciences, Department of Ophthalmology and Visual Science, Health Campus, Kubang Kerian, Kelantan, Malaysia.

Introduction: Cataract is a leading cause of visual impairment globally and in Malaysia, with surgery being the definitive treatment. While intracapsular cataract extraction (ICCE) is now less commonly performed due to advancements in surgical techniques, it remains essential in specific cases, such as those with weak zonular support. This study aims to evaluate the incidence, clinical profiles, and visual outcomes of patients who underwent ICCE, with or without intraocular lens (IOL) implantation, at Hospital Melaka, Malaysia, over the past decade.

View Article and Find Full Text PDF

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!