Impaired balance is common post stroke and can be assessed by means of force-platforms measuring center of pressure (COP) displacements during static standing, or more dynamically during lateral maximum weight shift (MWS). However, activities of daily life also include diagonal MWS and since force platforms are nowadays commercially available, investigating lateral and diagonal MWS in a clinical setting might be feasible and clinically relevant. We investigated lateral and diagonal MWS while standing in patients with stroke (PwS) and healthy controls (HC), evaluated MWS towards the affected and the non-affected side for PwS and correlated MWS with measures of balance, gait and fear of falling. In a cross-sectional observational study including 36 ambulatory sub-acute inpatients and 32 age-matched HC, a force platform (BioRescue, RM Ingénierie, France) was used to measure lateral and diagonal MWS in standing. Clinical outcome measures collected were Berg Balance Scale and Community Balance and Mobility Scale (CBMS) for balance, 10-meter walk test (10MWT) for gait speed and Falls Efficacy Scale-international version for fear of falling. MWS for PwS towards the affected side was significantly smaller compared to HC (lateral: p = 0.029; diagonal-forward: p = 0.000). MWS for PwS was also significantly reduced towards the affected side in the diagonal-forward direction (p = 0.019) compared to the non-affected side of PwS. Strong correlations were found for MWS for PwS in the diagonal-forward direction towards the affected side, and clinical measures of balance (CBMS: r = 0.66) and gait speed (10MWT: r = 0.66). Our study showed that ambulatory sub-acute PwS, in comparison to HC, have decreased ability to shift their body weight diagonally forward in standing towards their affected side. This reduced ability is strongly related to clinical measures of balance and gait speed. Our results suggest that MWS in a diagonal-forward direction should receive attention in rehabilitation of ambulatory sub-acute PwS in an inpatient setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5557488PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0183020PLOS

Publication Analysis

Top Keywords

lateral diagonal
16
diagonal mws
16
balance gait
12
fear falling
12
measures balance
12
ambulatory sub-acute
12
gait speed
12
mws pws
12
diagonal-forward direction
12
mws
11

Similar Publications

Ultrasonic detection of wrinkles in composites with gradual phase shift migration.

Ultrasonics

December 2024

School of Mechatronic & Automation Engineering, Shanghai University, Shanghai 200444, China; Key Laboratory of Silicate Cultural Relics Conservation (Shanghai University), Ministry of Education, China. Electronic address:

Fiber reinforced polymer composites (FRPs) are essential for various industrial fields, but wrinkles inside will greatly reduce their mechanical properties. Full-matrix capture (FMC) is a popular data structure for ultrasonic phased array imaging in composites. However, such structure may lead to data redundancy and noise interference.

View Article and Find Full Text PDF

Background: Hemophilic arthritis (HA) is associated with significant changes in the morphology of mature knee joints due to abnormal growth plate development. Previous studies have established marked distinctions between the femur and tibia of subjects with Haemophilia and those with osteoarthritis (OA). This study explored the morphological characteristics of the patella and patellofemoral joint in subjects with Haemophilia.

View Article and Find Full Text PDF

Transmissible topological edge states based on Su-Schrieffer-Heeger photonic crystals with defect cavities.

Nanophotonics

April 2024

State Key Laboratory for Mesoscopic Physics & Department of Physics, Collaborative Innovation Center of Quantum Matter & Frontiers Science Center for Nano-optoelectronics, Peking University, Beijing 100871, China.

Topological photonic crystals have great potential in the application of on-chip integrated optical communication devices. Here, we successfully construct the on-chip transmissible topological edge states using one-dimensional Su-Schrieffer-Heeger (SSH) photonic crystals with defect cavities on silicon-on-insulator slab. Different coupling strengths between the lateral modes and diagonal modes in photonic crystal defect cavities are used to construct the SSH model.

View Article and Find Full Text PDF

Aims: This study investigated the roles of lateral basal forebrain glial cell line-derived neurotrophic factor (GDNF) signaling and cholinergic neuron activity, apoptosis, and autophagy dysfunction in sleep deprivation-induced increased risk of chronic postsurgical pain (CPSP) in mice.

Methods: Sleep deprivation (6 h per day from -1 to 3 days postoperatively) was administered to mice receiving skin/muscle incision and retraction (SMIR) to determine whether perioperative sleep deprivation induces mechanical and thermal pain hypersensitivity, increases the risk of chronic pain, and causes changes of basal forebrain neurons activity (c-Fos immunostaining), apoptosis (cleaved Caspase-3 expression), autophagy (LC3 and p62 expression) and GDNF expression. Adeno-associated virus (AAV)-GDNF was microinjected into the basal forebrain to see whether increased GDNF expression could reverse sleep deprivation-induced changes in pain duration and cholinergic neuron apoptosis and autophagy.

View Article and Find Full Text PDF
Article Synopsis
  • Percutaneous screw fixation is a common treatment for posterior pelvic ring injuries, with transiliac-transsacral screws showing better biomechanical strength than bilateral sacroiliac screws, especially for less displaced bilateral sacral fractures.
  • An anatomical study on human cadaveric pelves identified a safe zone for screw placement in relation to the S1 region, categorizing most pelves as suitable for this technique while highlighting some as high-risk.
  • The research suggests using lateral fluoroscopic images to accurately identify safe entry points for screw placement at the S1 level, emphasizing the need for more studies with CT imaging to further validate these results.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!