Acetabular revisions using porous tantalum components: A retrospective study with 5-10 years follow-up.

World J Orthop

Francesco Roberto Evola, Luciano Costarella, Giuseppe Evola, Giuseppe Sessa, Department of Surgery, Orthopaedic Clinic, University of Catania, 95100 Catania, Italy.

Published: July 2017

Aim: To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions.

Methods: Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student's test for independent and paired samples. A value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method.

Results: The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student's test for paired samples: < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student's test for independent samples: > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component.

Conclusion: The medium-term use of prosthetic tantalum components in prosthetic hip revisions is safe and effective in a wide variety of acetabular bone defects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5534404PMC
http://dx.doi.org/10.5312/wjo.v8.i7.553DOI Listing

Publication Analysis

Top Keywords

student's test
12
tantalum components
8
prosthetic hip
8
radiolucent lines
8
implant mobilization
8
statistical analyses
8
test independent
8
paired samples
8
samples 005
8
cumulative survival
8

Similar Publications

Aim: The purpose of this study is to compare the efficacy of an artificial intelligence (AI)-based care plan learning strategy with standard training techniques in order to determine how it affects nursing students' learning results in newborn resuscitation.

Methods: Seventy third-year nursing students from a state university in Türkiye participated in the study. They were split into two groups: the experimental group, which received care plans based on AI, and the control group, which received traditional instruction.

View Article and Find Full Text PDF

Validity and Reliability of the Turkish Version of the Environmental Health Literacy Scale.

J Eval Clin Pract

February 2025

Faculty of Health Sciences, Department of Nursing, Division of Public Health Nursing, Bandırma Onyedi Eylül University, Balıkesir, Turkey.

Aim: This study aimed to translate the Environmental Health Literacy Scale (EHLS) into Turkish and assess its construct validity and internal consistency.

Methods: This research employs a methodological design. The research was conducted during the 2022-2023 academic year with a sample of 500 students from the Faculty of Health Sciences.

View Article and Find Full Text PDF

Globally, the prevalence of coronary artery disease (CAD) is increasing, accounting for a third of all deaths worldwide including myocardial infarctions (MIs) which represent the most severe clinical manifestation of CAD and are among the most dangerous coronary events. Therefore, this study aims to assess the knowledge of symptoms and risk factors of MIs, as well as attitudes and beliefs regarding MIs and confidence in recognizing CAD symptoms in Riyadh, Saudi Arabia. A cross-sectional study was conducted among individuals living in Riyadh, Saudi Arabia between November 2023 and April 2024 to assess their knowledge and beliefs about CAD and MIs.

View Article and Find Full Text PDF

The CRTS (China Railway Track System) II slab ballastless track is widely utilized in high-speed railway construction owing to its excellent structural integrity. However, its interfacial performance deteriorates under high-temperature conditions, leading to significant damage in structural details. Furthermore, the evolution of its performance under these conditions has not been comprehensively studied.

View Article and Find Full Text PDF

Very high heat is generated during the polymerization of poly (methyl methacrylate) (PMMA) bone cement, which is used for implant fixation in orthopedic surgery. As such, it has been suggested that irrigating the bone cement layer in the surgical site with a saline solution is a way of cooling the layer. In this study, we aimed to determine the influence of irrigation with a saline solution on the flexural strength and the microstructure of the test specimens of two PMMA bone cement brands: Simplex P and FIX 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!