Inter-Rater Reliability and Downstream Financial Implications of Electrocardiography Screening in Young Athletes.

Circ Cardiovasc Qual Outcomes

From the Cardiology Clinical and Academic Group (H.D., A.M., G.F., S.G., M.P., M.T., S.S.) and Institute of Infection and Immunity (I.C.S.), St. George's University of London, United Kingdom; Department of Cardiology, National University Heart Centre Singapore, Singapore, China (T.J.Y.); Service of Cardiology, Department of Medicine, Lausanne University Hospital, Lausanne, Switzerland (V.G.); Department of Cardiology, St Bartholomew's Hospital, London, United Kingdom (A.S., V.A.E.); Armed Forces Hospital, Luz Hospital and CEDOC-NOVA Medical School, Lisbon, Portugal (H.D.); Heart Rhythm Services, Division of Cardiology, Department of Medicine, University of British Columbia, Vancouver, Canada (G.M.); Infanta Cristina Hospital, Badajoz, Spain (C.G.-C.); University Hospital Birmingham, Birmingham, United Kingdom (B.E.); and William Harvey Hospital, Ashford, United Kingdom (V.J.).

Published: August 2017

Background: Preparticipation screening for cardiovascular disease in young athletes with electrocardiography is endorsed by the European Society of Cardiology and several major sporting organizations. One of the concerns of the ECG as a screening test in young athletes relates to the potential for variation in interpretation. We investigated the degree of variation in ECG interpretation in athletes and its financial impact among cardiologists of differing experience.

Methods And Results: Eight cardiologists (4 with experience in screening athletes) each reported 400 ECGs of consecutively screened young athletes according to the 2010 European Society of Cardiology recommendations, Seattle criteria, and refined criteria. Cohen κ coefficient was used to calculate interobserver reliability. Cardiologists proposed secondary investigations after ECG interpretation, the costs of which were based on the UK National Health Service tariffs. Inexperienced cardiologists were more likely to classify an ECG as abnormal compared with experienced cardiologists (odds ratio, 1.44; 95% confidence interval, 1.03-2.02). Modification of ECG interpretation criteria improved interobserver reliability for categorizing an ECG as abnormal from poor (2010 European Society of Cardiology recommendations; κ=0.15) to moderate (refined criteria; κ=0.41) among inexperienced cardiologists; however, interobserver reliability was moderate for all 3 criteria among experienced cardiologists (κ=0.40-0.53). Inexperienced cardiologists were more likely to refer athletes for further evaluation compared with experienced cardiologists (odds ratio, 4.74; 95% confidence interval, 3.50-6.43) with poorer interobserver reliability (κ=0.22 versus κ=0.47). Interobserver reliability for secondary investigations after ECG interpretation ranged from poor to fair among inexperienced cardiologists (κ=0.15-0.30) and fair to moderate among experienced cardiologists (κ=0.21-0.46). The cost of cardiovascular evaluation per athlete was $175 (95% confidence interval, $142-$228) and $101 (95% confidence interval, $83-$131) for inexperienced and experienced cardiologists, respectively.

Conclusions: Interpretation of the ECG in athletes and the resultant cascade of investigations are highly physician dependent even in experienced hands with important downstream financial implications, emphasizing the need for formal training and standardized diagnostic pathways.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCOUTCOMES.116.003306DOI Listing

Publication Analysis

Top Keywords

interobserver reliability
20
experienced cardiologists
20
young athletes
16
ecg interpretation
16
inexperienced cardiologists
16
95% confidence
16
confidence interval
16
european society
12
society cardiology
12
cardiologists
12

Similar Publications

Evaluation of Peer Review of Percutaneous Coronary Intervention Operator Performance.

Circ Cardiovasc Qual Outcomes

January 2025

Division of Cardiology, Department of Medicine, University of Washington, Seattle (J.A.D., E.J.S., D.H.A.).

Background: Case-based peer review of percutaneous coronary intervention (PCI) is used by many hospitals for quality improvement and to make decisions regarding physician competency. However, there are no studies testing the reliability or validity of peer review for PCI performance evaluation.

Methods: We recruited interventional cardiologists from 12 Veterans Affairs Health System facilities throughout the United States to provide PCI cases for review.

View Article and Find Full Text PDF

Background: The most commonly used classification for proximal fifth metatarsal fractures has not shown good reproducibility. The aim of this study was to evaluate the intraobserver and interobserver agreement of a new classification system for such fractures.

Methods: The study involved the development of a novel classification system that categorized these fractures into 2 main types and 2 subtypes.

View Article and Find Full Text PDF

Purpose: This study was performed to introduce, evaluate, and compare various novel assessment protocols designed for straightforward, reliable, and reproducible measurement of alveolar bone levels. These protocols are intended for standardized periodontal assessment and follow-up, utilizing cone-beam computed tomography (CBCT) images and manipulation of Digital Imaging and Communications in Medicine (DICOM) viewer software.

Materials And Methods: Two experienced oral and maxillofacial radiologists developed 5 distinct radiographic measurement protocols.

View Article and Find Full Text PDF

Validation of a novel tool for automated tooth modelling by fusion of CBCT-derived roots with the respective IOS-derived crowns.

J Dent

December 2024

OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden. Electronic address:

Article Synopsis
  • This study aimed to validate a novel AI tool that combines dental images from two different sources, cone beam computed tomography (CBCT) and intraoral scanners (IOS), to create accurate tooth models.
  • The evaluation involved analyzing a dataset from 30 patients, calculating various accuracy metrics for the AI-generated models, and comparing them to both expert manual methods and existing segmentation approaches.
  • Results indicated that the AI-based approach achieved high accuracy similar to manual methods but was significantly faster, suggesting it could improve efficiency in dental practices.
View Article and Find Full Text PDF

Purpose: This study aims to evaluate the inter-observer variability in assessing the optic disc in fundus photographs and its implications for establishing ground truth in AI research.

Methods: Seventy subjects were screened during a screening campaign. Fundus photographs were classified into normal (NL) or abnormal (GS: glaucoma and glaucoma suspects) by two masked glaucoma specialists.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!