Ventricular safety pacing (VSP) is used to avoid cross talk by delivering ventricular stimulus shortly after an atrial-paced event if ventricular-sensed event occurs. Although VSP is a protective feature that exists for decades in different pacing devices, there are some reports of unfavorable outcomes of this algorithm. More so, health care providers sometimes face difficulties in interpreting and dealing with VSP strips. This case report discusses an important pacemaker algorithm and encourages further attention to possible pitfalls and hence avoids unnecessary interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484548PMC
http://dx.doi.org/10.1177/1179546817714478DOI Listing

Publication Analysis

Top Keywords

pacing spikes
4
spikes ventricular
4
ventricular safety
4
safety pacing
4
pacing vsp
4
vsp avoid
4
avoid cross
4
cross talk
4
talk delivering
4
delivering ventricular
4

Similar Publications

Zebra finches undergo a gradual refinement of their vocalizations, transitioning from variable juvenile songs to the stereotyped song of adulthood. To investigate the neural mechanisms underlying song crystallization-a critical phase in this developmental process-we performed intracellular recordings in HVC (a premotor nucleus essential for song learning and production) of juvenile birds. We then compared these recordings to previously published electrophysiological data from adult birds.

View Article and Find Full Text PDF

Triple pacing spikes on QRST: What is the mechanism?

J Electrocardiol

January 2025

Department of Cardiology, Electrophysiology division, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala 695011, India. Electronic address:

A septuagenarian man underwent dual chamber pacemaker (DDDR - Boston Scientific Massachusetts, U.S.) insertion for a complete heart block.

View Article and Find Full Text PDF

Biotronik Implantable Cardioverter Defibrillator for Measurement of Intrathoracic Impedance: A Report of Two Cases.

Ann Noninvasive Electrocardiol

November 2024

Department of Cardiovascular Medicine, Heart Center, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China.

Article Synopsis
  • Two patients received an implantable cardioverter-defibrillator (ICD), and Holter analysis revealed regular pacing spikes occurring after heartbeats, indicating system activity.
  • The study utilized dynamic electrocardiogram analysis and literature review to identify these spikes as a feature measuring thoracic impedance rather than a malfunction.
  • The findings suggest that these spikes are a normal function of the ICD designed to monitor heart failure, not an interference signal.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!