A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of splicing assays to detect an intronic variant of the OCRL gene in Lowe syndrome. | LitMetric

Lowe syndrome is an X-linked inherited disorder diagnosed by congenital cataracts, intellectual impairment, and renal tubular dysfunction. It is caused by pathogenic variants of the oculocerebrorenal syndrome of Lowe gene (OCRL), of which more than 250 have been reported so far. Around 30 of these variants are intronic nucleotide changes; however, to show the pathogenicity of these variants is usually laborious. In this report, we conducted genetic testing of a patient clinically diagnosed with Lowe syndrome to detect the presence of OCRL variants. We analyzed variant transcript expression in peripheral blood leukocytes and using a minigene construct in addition to in silico analysis. We detected a 9 base pair intronic insertion between OCRL exon 10 and exon 11 derived from the alteration of the splicing acceptor site in intron 10 caused by the intronic splicing variant NM_000276.3: c.940-11G>A (p.Lys313_Val314insAsnSer*). The findings obtained from transcript analysis of peripheral blood leukocytes and the minigene construct assay were identical to those of in silico analysis. All assays detected the same transcript abnormality and were reliable in revealing the pathogenicity of the intronic variant. The in vitro assay can also be used to clarify the complicated splicing mechanisms in inherited kidney diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmg.2017.08.001DOI Listing

Publication Analysis

Top Keywords

lowe syndrome
12
intronic variant
8
syndrome lowe
8
peripheral blood
8
blood leukocytes
8
leukocytes minigene
8
minigene construct
8
silico analysis
8
intronic
5
comparison splicing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!