Capillary electrophoresis and electrokinetic chromatography are typically carried out in unmodified fused-silica capillaries under conditions that result in a strong negative zeta potential at the capillary wall and a robust cathodic electroosmotic flow. Modification of the capillary wall to reverse the zeta potential and mask silanol sites can improve separation performance by reducing or eliminating analyte adsorption, and is essential when conducting electrokinetic chromatography separations with cationic latex nanoparticle pseudo-stationary phases. Semipermanent modification of the capillary walls by coating with cationic polymers has proven to be facile and effective. In this study, poly([2-(acryloyloxy)ethyl]trimethylammonium chloride) polymers were synthesized by reversible addition-fragmentation chain transfer polymerization and used as physically adsorbed semipermanent coatings for capillary electrophoresis and electrokinetic chromatography separations. An initial synthesis of poly([2-(acryloyloxy)ethyl]trimethylammonium chloride) polymer coating produced strong and stable anodic electroosmotic flow of -5.7 to -5.4 × 10 cm /V⋅s over the pH range of 4-7. Significant differences in the magnitude of the electroosmotic flow and effectiveness were observed between synthetic batches, however. For electrokinetic chromatography separations, the best performing batches of poly([2-(acryloyloxy)ethyl]trimethylammonium chloride) polymer performed as well as the commercially available cationic polymer polyethyleneimine, whereas polydiallylammonium chloride and hexadimethrine bromide did not perform well.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201700461DOI Listing

Publication Analysis

Top Keywords

electrokinetic chromatography
20
poly[2-acryloyloxyethyl]trimethylammonium chloride
16
chromatography separations
16
capillary electrophoresis
12
electrophoresis electrokinetic
12
electroosmotic flow
12
cationic polymer
8
zeta potential
8
capillary wall
8
modification capillary
8

Similar Publications

A rapid and sensitive enrichment technique, field enhanced sample injection-dynamic pH junction-sweeping (FESI-DypH-sweeping) was successfully developed for the simultaneous separation and concentration of alkaloids and stereoisomers of Uncariae ramulus cum uncis (UR) by cyclodextrin electrokinetic chromatography (CDEKC) with diode array detection system. The sample was prepared in a low-conductivity (FESI), low-pH (DypH) sample matrix (4 mM phosphate buffer, 3% methanol, pH=3), and the background electrolyte (BGE) consisted of a high-conductivity, high-pH buffer (40 mM phosphate buffer, pH 7.0, 8 mg/mL carboxymethyl-β-cyclodextrin, and 30% methanol).

View Article and Find Full Text PDF

Human serum transferrin can bind up to two iron atoms, one in each of its two domains which are known as the N-lobe and the C-lobe. Ferric pyrophosphate and ferric citrate have been shown to direct loading into the C-lobe and N-lobe, respectively. We report that the iron supplement ferric pyrophosphate citrate directs iron to the C-lobe.

View Article and Find Full Text PDF

The measurement of selected norepinephrine metabolites, such as 3,4-dihydroxyphenylglycol (DHPG), 3-methoxy-4-hydroxyphenylethylenglycol (MHPG), and vanillylmandelic acid (VMA), in biological matrices-including urine-is of great clinical importance for the diagnosis and monitoring of diseases. This fact has forced researchers to evaluate new analytical methodologies for their isolation and preconcentration from biological samples. In this study, the three most popular extraction techniques-liquid-liquid extraction (LLE), solid-phase extraction (SPE), and a new 3D-printed system for dispersive solid-phase extraction (3D-DSPE)-were investigated.

View Article and Find Full Text PDF

A novel, deep eutectic solvent (DES)-assisted sodium cholate (SC)-chiral microemulsion electrokinetic chromatography method is presented for separation of five flavonoid glycoside enantiomers, namely hesperidin, naringin, narirutin, eriocitrin, and neoeriocitrin. Herein, we develop a novel, green DES, whose addition considerably enhances the separation performance through multiple synergistic effects. A series of factors notably affecting chiral separation are systematically optimized: type and concentration of cyclodextrin, DES, and SC, oil phase type, and pH.

View Article and Find Full Text PDF

A method was developed for studying mass transfer kinetics at lipid bilayers of liposomes. Elution peaks of coumarin were measured by liposome electrokinetic chromatography (LEKC). Four types of phospholipids having different alkyl chains were used for preparing liposomes, which were used as pseudo-stationary phases in LEKC systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!