Background: The purpose of this study was to evaluate the accuracy of pedicle screw placement, its advantages, and limitations in posterior instrumentation of thoracolumbar and lumbar burst fractures assisted only by lateral fluoroscopic imaging.

Materials And Methods: Pre- and postoperative computerized tomographic (CT) scans of 117 patients with thoracolumbar and lumbar burst fractures, who underwent posterior instrumentation with pedicle screw fixation, were prospectively analyzed. Accuracy of screw placement, reconstruction of the vertebral height, and correction of the kyphotic angle were studied. Position of the pedicle screws were determined, and cortical breach was graded on the postoperative axial CT scans. Percentage of vertebral height reconstruction and kyphotic angle correction were calculated from the postoperative midsagittal CT scans.

Results: Four hundred and sixty-eight pedicle screws in 234 motion segments were included in this study. 427 screws were centrally placed with an accuracy rate of 91.24%. Out of the 41 (8.76%) screws that breached the pedicle wall, 32 (6.84%) screws had violated the medial wall, while 9 (1.92%) screws breached the lateral wall. There were no "air-ball" screws. No screw penetrated the anterior wall. Postoperatively, none of the patients deteriorated neurologically, and no screw required revision. Postoperatively, there was significant restoration of vertebral height and correction of kyphosis (P < 0.05).

Conclusion: Pedicle fixation performed on a Relton-Hall frame is relatively simple and, when performed carefully using only lateral fluoroscopic imaging, has a lower potential for complications due to cortical breach.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12306-017-0498-4DOI Listing

Publication Analysis

Top Keywords

pedicle screw
12
thoracolumbar lumbar
12
screw placement
12
vertebral height
12
screw fixation
8
assisted lateral
8
lateral fluoroscopic
8
study evaluate
8
evaluate accuracy
8
accuracy screw
8

Similar Publications

Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.

View Article and Find Full Text PDF

Clinical applications of 3D printing in spine surgery: a systematic review.

Eur Spine J

January 2025

In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.

Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.

Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.

View Article and Find Full Text PDF

Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF

Objective: We aimed to investigate the incidence of delayed-onset neurological deficits (DONDs), DOND-related reoperation rates following adult spinal deformity (ASD) surgery, and efficacy of transverse process hooks (TPHs) at the uppermost instrumented vertebra (UIV) compared to pedicle screws (PSs).

Methods: We included 90 consecutive patients who underwent instrumented fusion from the sacrum to the distal thoracic spine for ASD, with a minimum follow-up of 24 months. Clinical and radiological outcomes were compared between 33 patients in the TPH group and 57 patients in the PS group, using the Scoliosis Research Society-22 Outcomes questionnaire (SRS-22), Medical Outcomes Study Questionnaire Short-Form 36 (SF-36), and various spinal sagittal parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!