  • The SEAS study evaluated the link between transaortic flow rate (FR) and health outcomes in 1,661 patients with aortic valve stenosis (AS), focusing on whether low flow rates affect mortality.
  • Low transaortic FR, defined as less than 200 ml/s, was observed in 21% of patients and was more common in older individuals, women, and those with inconsistent AS severity.
  • Results indicated that low transaortic FR significantly increased the risk of both cardiovascular and all-cause mortality, even after adjusting for various health factors, highlighting its importance in patient prognosis.

Article Abstract

Objectives: The association of transaortic flow rate (FR) with outcomes was tested in 1,661 patients with aortic valve stenosis (AS) in the SEAS (Simvastatin and Ezetimibe in Aortic Stenosis) study.

Background: Low transaortic flow may complicate grading of AS. However, the association of lower transaortic FR with adverse outcomes has not been reported.

Methods: Transaortic FR was calculated from Doppler-derived stroke volume in milliliters divided by systolic ejection time in seconds and considered low if <200 ml/s. The association of transaortic FR with cardiovascular and all-cause mortality during 4.3-year follow-up was tested in time-varying Cox regression models run with aortic valve replacement as competing risk and reported as hazard ratio (HR) and 95% confidence interval (CI).

Results: Low transaortic FR was found in 21% of patients at baseline. Patients with low transaortic FR were older, had lower systemic arterial compliance and left ventricular mass, and included more women and patients with inconsistently graded severe AS and low stroke volume index (<35 ml/m) (p < 0.01 for all). Low in-study transaortic FR was associated with higher rates of cardiovascular and all-cause mortality both in unadjusted analyses (HR: 2.56 [95% CI: 1.62 to 4.04]; and HR: 1.93 [95% CI: 1.35 to 2.75], respectively; p < 0.001 for both) and after adjustment for age, sex, randomized study treatment, hypertension, stroke volume index <35 ml/m, LV mass, and mean aortic gradient (HR: 2.79 [95% CI: 1.65 to 4.73]; and HR: 1.90 [95% CI: 1.27 to 2.84], respectively; p < 0.01 for both).

Conclusions: In patients with AS without known cardiovascular disease or diabetes, low transaortic FR was independently associated with higher rates of cardiovascular and all-cause mortality. (An Investigational Drug on Clinical Outcomes in Patients With Aortic Stenosis (Narrowing of the Major Blood Vessel of the Heart) (MK-0653A-043 AM4); NCT00092677).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2017.05.008DOI Listing

Publication Analysis

Top Keywords

transaortic flow
12
lower transaortic
8
flow rate
8
rate associated
4
associated increased
4
increased mortality
4
mortality aortic
4
aortic valve stenosis
4
valve stenosis objectives
4
objectives association
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!