A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical Note: The effect of 2D excitation profile on T1 measurement accuracy using the variable flip angle method with an average flip angle assumption. | LitMetric

Purpose: To study the accuracy and precision of T estimates using the Variable Flip Angle (VFA) method in 2D and 3D acquisitions.

Methods: Excitation profiles were simulated using numerical implementation of the Bloch equations for Hamming-windowed sinc excitation pulses with different time-bandwidth products (TBP) of 2, 6, and 10 and for T values of 295 ms and 1045 ms. Experimental data were collected in 5° increments from 5° to 90° for the same T and TBP values. T was calculated for every combination of flip angle with and without a correction for B and slice profile variation. Calculations were also made for flat slice profile such as obtained in 3D acquisition. Monte Carlo simulations were performed to obtain T measurement uncertainty.

Results: VFA T measurements in 2D without correction can result in a 40-80% underestimation of true T . Flip angle correction can reduce the underestimation, but results in accurate measurements of T only within a narrow band of flip angle combinations. The narrow band of accuracy increases with TBP, but remains too narrow for any practical range of T values or B variation. Simulated noisy VFA T measurements in 3D were accurate as long as the two angles chosen are on either side of the Ernst angle.

Conclusions: Accurate T1 estimates from VFA 2D acquisitions are possible, but only a narrow range of T1 values within a narrow range of flip angle combinations can be accurately calculated using a 2D slice. Unless a better flip angle correction method is used, these results demonstrate that accurate measurements of T1 in 2D cannot be obtained robustly enough for practical use and are more likely obtained by a thin slab 3D VFA acquisition than from multiple-slice 2D acquisitions. VFA T measurements in 3D are accurate for wide ranges of flip angle combinations and T values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689072PMC
http://dx.doi.org/10.1002/mp.12513DOI Listing

Publication Analysis

Top Keywords

flip angle
36
angle correction
12
vfa measurements
12
angle combinations
12
flip
9
angle
9
variable flip
8
tbp values
8
slice profile
8
accurate measurements
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!