Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Detrusor sphincter dyssynergia affects 70% to 80% of all spinal cord injury patients, resulting in increased risk of urinary tract infections (UTIs) and potential exposure to antimicrobial resistance. In Brazil, local guidelines recommend intermittent catheterization as the best method for bladder emptying, and two catheter types are available: the conventional uncoated PVC and the hydrophilic coated catheters.
Objective: To evaluate the cost-effectiveness of two types of catheters for intermittent catheterization from the perspective of the Brazilian public healthcare system.
Materials And Methods: A Markov model was used to evaluate cost-effectiveness in those with spinal cord injuries. A primary analysis was conducted on all possible adverse events, and a secondary analysis was performed with urinary tract infections as the only relevant parameter. The results were presented as cost per life years gained (LYG), per quality-adjusted life years (QALY) and per number of urinary tract infections (UTIs) avoided.
Results: The base scenario of all adverse events shows a cost-effective result of hydrophilic coated catheters compared to uncoated PVC catheters at 57,432 BRL (Brazilian Reais) per LYG and 122,330 BRL per QALY. The secondary scenario showed that the use of hydrophilic coated catheters reduces the total number of UTIs, indicating that an additional cost of hydrophilic coated catheters of 31,240 BRL over a lifetime will reduce lifetime UTIs by 6%.
Conclusions: Despite the higher unit value, the use of hydrophilic coated catheters is a cost-effective treatment from the perspective of the Brazilian public healthcare system.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5815542 | PMC |
http://dx.doi.org/10.1590/S1677-5538.IBJU.2017.0221 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!