Crucial benefits provided by partially coherent light microscopy such as improved spatial resolution, optical sectioning and speckle-noise suppression are exploited here to achieve 3D quantitative imaging: reconstruction of the object refractive index (RI). We present a partially coherent optical diffraction tomography technique (PC-ODT) that can be easily implemented in commercially available bright-field microscopes. We show that the high numerical apertures of the objective and condenser lenses, together with optical refocusing, are main issues for achieving fast and successful 3D RI reconstruction of weak objects. In particular, the optical refocusing is performed by a high-speed focus tunable lens mounted in front of the digital camera enabling compatibility with commercial microscopes. The technique is experimentally demonstrated on different examples: diatom cells (biosilica shells), polystyrene micro-spheres and blood cells. The results confirm the straightforward 3D-RI reconstruction of the samples providing valuable quantitative information for their analysis. Thus, the PC-ODT can be considered as an efficient and affordable alternative to coherent ODT which requires specially designed holographic microscopes.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.25.015699DOI Listing

Publication Analysis

Top Keywords

partially coherent
12
coherent light
8
light microscopy
8
optical refocusing
8
label-free quantitative
4
quantitative tomographic
4
tomographic imaging
4
imaging partially
4
coherent
4
microscopy crucial
4

Similar Publications

The behavior of triple-cation mixed halide perovskite solar cells (PSCs) under ultrashort laser pulse irradiation at varying fluences is investigated, with a focus on local heating effects observed in femtosecond transient absorption (TA) studies. The carrier cooling time constant is found to increase from 230 fs at 2 µJ cm⁻ to 1.3 ps at 2 mJ cm⁻ while the charge population decay accelerates from tens of nanoseconds to the picosecond range within the same fluence range.

View Article and Find Full Text PDF

A co-registration method to validate optical coherence tomography in the breast surgical cavity.

Heliyon

January 2025

BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.

Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.

View Article and Find Full Text PDF

Background: According to the model of the glymphatic system, the directed flow of cerebrospinal fluid (CSF) is a driver of waste clearance from the brain. In sleep, glymphatic transport is enhanced, but it is unclear how it is affected by anesthesia. Animal research indicates partially opposing effects of distinct anesthetics but corresponding results in humans are lacking.

View Article and Find Full Text PDF

We outline two general theoretical techniques to simulate polariton quantum dynamics and optical spectra under the collective coupling regimes described by a Holstein-Tavis-Cummings (HTC) model Hamiltonian. The first one takes advantage of sparsity of the HTC Hamiltonian, which allows one to reduce the cost of acting polariton Hamiltonian onto a state vector to the linear order of the number of states, instead of the quadratic order. The second one is applying the well-known Chebyshev series expansion approach for quantum dynamics propagation and to simulate the polariton dynamics in the HTC system; this approach allows us to use a much larger time step for propagation and only requires a few recursive operations of the polariton Hamiltonian acting on state vectors.

View Article and Find Full Text PDF

Objective: To better understand the clinical phenotype of Ménière's disease (MD), we examined family history, thyroid disorder, migraine, and associated disorders in complaints of people living with MD.

Method: We designed the study as a retrospective and examined data gathered from 912 participants with MD. Their data were originally collected by the Finnish Ménière Federation (FMF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!