Background And Aims: This experimental study mainly aims at comparing the most important mechanical properties of the new orthodontic archwires, those immersed in fluorinated solution, the as-retrieved ones and the intra-oral used ones.

Methods: A total of 270 arch wires were tested, using tensile testing and three-point bending tests. The tested archwires were made of Stainless Steel, Nickel Titanium, Beta-Titanium and physiognomic covered Nickel Titanium. The tested archwires were subjected to three types of treatments: immersion into fluorinated solution, immersion into carbonated drinks and intra-oral use.

Results: The immersion caused variations of the activation and deactivation forces of all arch wires. The most affected arch wires, in terms of bending characteristics, were the intra-oral used ones.

Conclusions: The alteration of mechanical properties of the orthodontic arch wires by their immersion into fluorinated solutions and soft drinks could not be statistically demonstrated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5536211PMC
http://dx.doi.org/10.15386/cjmed-729DOI Listing

Publication Analysis

Top Keywords

arch wires
16
mechanical properties
12
orthodontic archwires
8
properties orthodontic
8
fluorinated solution
8
tested archwires
8
nickel titanium
8
immersion fluorinated
8
evaluation mechanical
4
properties surface
4

Similar Publications

Research progress on surface modification and coating technologies of biomedical NiTi alloys.

Colloids Surf B Biointerfaces

January 2025

College of New Energy and Materials, China University of Petroleum, Beijing 102249, China. Electronic address:

NiTi alloys are an important class of biomaterials with extensive clinical applications such as cardiovascular stents, orthodontic arch-wires, esophageal stents, orthopedic implants and more. However, the long-term implantation of NiTi alloys presents significant challenges due to their susceptibility to wear, corrosion and the excessive release of harmful nickel ions. These factors can severely compromise both the biocompatibility and the overall service life of the implants.

View Article and Find Full Text PDF

Accidental ingestion of foreign bodies frequently necessitates emergency department visits, with many cases requiring surgical consultation. Although most ingested items pass through the gastrointestinal tract uneventfully, orthodontic components, such as wires, present a specific risk due to their shape and material properties. This report describes a rare case of a 13-year-old male adolescent whose initial presentation suggested ingestion of a chicken bone.

View Article and Find Full Text PDF

Distal augmentation in unstable distal clavicle fractures: a retrospective cohort study of 101 cases.

Arch Orthop Trauma Surg

January 2025

The Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123, Ta Pei Road, Niao Sung Dist, Kaohsiung, Taiwan.

Introduction: The optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.

View Article and Find Full Text PDF

Objective: This study aims to compare the impact of titanium and stainless steel (SS) retainer wires on lower incisor stability and periodontal health.

Methods: Fifty patients between the ages of 14.1 and 29.

View Article and Find Full Text PDF

Objectives: To compare the biomechanics of labial and lingual fixed orthodontic treatment options for a simulated curve of Spee malocclusion.

Materials And Methods: An in vitro electromechanical orthodontic simulator was used to measure the three-dimensional forces and moments on each tooth of a mandibular arch. Labial and lingual brackets, both with 0.

View Article and Find Full Text PDF