Purpose: To determine the field efficacy of an earmuff used by the employees of a private company.

Methods: Measurements were performed using a double-channel noise dosimeter. Noise levels collected in one-third-octave bands were corrected with the frequency response for diffuse sound field and attenuation was compared with values provided by the manufacturer of the hearing protection device (HPD).

Results: Comparisons between the corrected noise reduction and the attenuation provided by the manufacturer of the HPD show no statistically significant differences in attenuation for most frequency bands, with higher mean values for the observed corrected noise reduction. However, despite the fact that the field attenuation values are above those obtained in the laboratory, when individual attenuation values were compared with expected attenuation values it was found that the employees have below-expected noise attenuation in all frequency bands.

Conclusions: The fact that over 60% of the employees had frequency band attenuations below that expected for most frequency bands underscores the need for individual assessment of attenuation provided by the HPD in the workplace, to assess whether the HPD is functional and what provisions should be implemented in a specific workplace.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10803548.2017.1333247DOI Listing

Publication Analysis

Top Keywords

attenuation values
12
attenuation
8
field attenuation
8
provided manufacturer
8
corrected noise
8
noise reduction
8
attenuation provided
8
attenuation frequency
8
frequency bands
8
noise
5

Similar Publications

Introduction: Japanese encephalitis virus (JEV) and Zika virus (ZIKV) are prevalent in over 80 countries or territories worldwide, causing hundreds of thousands of cases annually. But currently there is a lack of specific antiviral agents and effective vaccines.

Methods: In the present study, to identify human neutralizing monoclonal antibody (mAb) against JEV or/and ZIKV, we isolated ZIKV-E protein-binding B cells from the peripheral venous blood of a healthy volunteer who had received the JEV live-attenuated vaccine and performed 10× Genomics transcriptome sequencing and BCR sequencing analysis, we then obtained the V region amino acid sequences of a novel mAb LZY3412.

View Article and Find Full Text PDF

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.

View Article and Find Full Text PDF

Objective: To perform a systematic review and meta-analysis to assess the relationship between intraprostatic maximum standardised uptake value (SUV) of the dominant prostatic lesion as measured on preoperative prostate-specific membrane antigen (PSMA) positron emission tomography (PET) with radical prostatectomy International Society of Urological Pathology (ISUP) Grade Group, pathological tumour (pT) staging, and biochemical recurrence (BCR).

Methods: Prostate-specific membrane antigen PET may offer non-invasive assessment of histopathological and oncological outcomes before definitive treatment. SUV of the dominant lesion has been explored as a prognostic biomarker.

View Article and Find Full Text PDF

Fabrication of heavy density mortar using aggregates reinforced with available solid inorganic chemical additives is of a great importance as a protective layer to mitigate radiations in nuclear facilities. The effect of lead oxide and borax decahydrate on the hydration kinetics was evaluated by determining setting time, leachability and compressive strength. To speed up the reaction, 0.

View Article and Find Full Text PDF

Objective: Discriminating between hemorrhage and iodine extravasation can pose challenges in conventional computed tomography (CCT) images following preoperative embolization for meningioma. This study aimed to assess the efficacy of dual-energy computed tomography (DECT) in differentiating hemorrhage from iodine extravasation after preoperative embolization for meningioma.

Methods: Twenty-one consecutive meningioma patients who underwent CCT before and DECT immediately after preoperative embolization were included in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!