The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R)-[C]verapamil imaging on the same day using a GE-Advance (PET-only) and a Siemens Biograph mMR system (PET/MR). PET-emission data were reconstructed using a transmission-based attenuation correction (AC) map (PET-only), whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K and k) and distribution volume (V ). Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA). Comparison of DIXON-based AC (PET/MR) with emission data derived from the PET-only system revealed average inter-system differences of -33 ± 14% ( < 0.05) for the K parameter and -19 ± 9% ( < 0.05) for k. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of -16 ± 18% for K and -9 ± 10% for k. The average differences in V were -18 ± 10% ( < 0.05) for DIXON- and -8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods. www.clinicaltrialsregister.eu, identifier 2013-001724-19.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5511842 | PMC |
http://dx.doi.org/10.3389/fnins.2017.00396 | DOI Listing |
Sports Biomech
January 2025
Department of Physical Education, Jeonbuk National University, Jeonju, Republic of Korea.
The arm slot (AS) angle reflects the pitching style of baseball pitchers. Baseball pitchers at different levels exhibit different AS angle distributions and different pitching mechanics. The present study divided 66 elite baseball pitchers from the Open Biomechanics database into 3 groups based on AS angles: ASMi, ASMo, ASMa.
View Article and Find Full Text PDFFront Microbiol
December 2024
Oniris VetAgroBio, INRAE, SECALIM, Nantes, France.
Our study aims to assess the thermal inactivation of non-proteolytic type B spores in a plant-based fish and to evaluate the potential of alternative heat treatments at temperatures below the safe harbor guidelines established for vacuum-packed chilled products of extended durability. First, the heat resistance of the spore suspension was determined using capillary tubes in potassium phosphate buffer at 80°C. The D value was estimated to be 0.
View Article and Find Full Text PDFJ Chem Theory Comput
January 2025
Department of Electrical & Computer Engineering, Stony Brook University, Stony Brook, New York 11794, United States.
In this work, we develop a novel Bayesian approach to study the adsorption and desorption of CO onto a Pd(111) surface, a process of great importance in natural sciences. The motivation for this work comes from the recent availability of time-resolved infrared spectroscopy data and the need for model interpretability and uncertainty quantification in chemical processes. The objective is to learn the relevant parameters that characterize the process: coverage with time, rate constants, activation energies, and pre-exponential factors.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
January 2025
Amsterdam UMC location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands.
Purpose: The aim of this study was to validate simplified methods for quantifying [Ga]Ga-FAPI-46 uptake against full pharmacokinetic modeling.
Methods: Ten patients with pancreatobiliary cancer underwent a 90-min dynamic PET/CT scan using a long axial field of view system. Arterial blood samples were used to establish calibrated plasma-input function from both continuous arterial sampling and image-derived input function (IDIF).
Biochim Biophys Acta Proteins Proteom
December 2024
Departamento de Física, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral and CONICET, S3000ZAA Santa Fe, Argentina.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!