A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of exposure parameters and iterative reconstruction on automatic airway segmentation and analysis on MDCT-An ex vivo phantom study. | LitMetric

Objectives: To evaluate the influence of exposure parameters and raw-data-based iterative reconstruction (IR) on computer-aided segmentation and quantitative analysis of the tracheobronchial tree on multidetector computed tomography (MDCT).

Material And Methods: 10 porcine heart-lung-explants were mounted inside a dedicated chest phantom. MDCT was performed at 120kV and 80kV with 120, 60, 30 and 12 mAs each. All scans were reconstructed with filtered back projection (FBP) or IR, resulting in a total of 160 datasets. The maximum number of detected airway segments, most peripheral airway generation detected, generation-specific airway wall thickness (WT), total diameter (TD) and normalized wall thickness (pi10) were compared.

Results: The number of detected airway segments decreased slightly with dose (324.8±118 at 120kV/120mAs vs. 288.9±130 at 80kV/30mAs with FBP, p<0.05) and was not changed by IR. The 20th generation was constantly detected as most peripheral. WT did not change significantly with exposure parameters and reconstruction algorithm across all generations: range 1st generation 2.4-2.7mm, 5th 1.0-1.1mm, and 10th 0.7mm with FBP; 1st 2.3-2.4mm, 5th 1.0-1.1mm, and 10th 0.7-0.8mm with IR. pi10 was not affected as well (range 0.32-0.34mm).

Conclusions: Exposure parameters and IR had no relevant influence on measured airway parameters even for WT <1mm. Thus, no systematic errors would be expected using automatic airway analysis with low-dose MDCT and IR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5540604PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0182268PLOS

Publication Analysis

Top Keywords

influence exposure
8
exposure parameters
8
iterative reconstruction
8
number detected
8
detected airway
8
airway segments
8
wall thickness
8
airway
5
parameters iterative
4
reconstruction automatic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!