AI Article Synopsis

  • The Vitamin D Standardization Program (VDSP) has created tools to help labs standardize tests for 25-hydroxyvitamin D, ensuring accuracy in laboratory results.
  • The paper outlines specific steps for labs to follow, including initial calibration and assessment of accuracy, which can apply to both commercial and in-house testing methods.
  • Labs are encouraged to maintain a total coefficient of variation (CV) of ≤10% and a mean bias of ≤5%, with guidance provided for achieving these goals using various approaches.

Article Abstract

The Vitamin D Standardization Program (VDSP) has collaborated with numerous groups and agencies to assemble a set of tools, i.e., a reference measurement system, that can be used to establish the traceability of 25-hydroxyvitamin D [25(OH)D] assays to relevant reference measurement procedures and reference materials. This is done with the goal of verifying end-user laboratory performance using precise statistical criteria to determine whether a specific assay is standardized. The purpose of this paper was to outline a set of steps that routine clinical and research laboratories can use to standardize their 25(OH)D assays using these tools. These steps apply to laboratories using commercially developed immunoassay measurement systems as well as in-house assays, usually based on high HPLC or LC tandem MS measurement systems. The steps are (1) initial calibration, (2) initial assessment of accuracy and bias, (3) assessment of total percent CV and mean bias, (4) use of trueness controls, and (5) participation in accuracy-based performance testing and/or external quality assessment schemes. The goal of each laboratory assay is to have a total CV of ≤10% and mean bias of ≤5%. Rigorous and less rigorous but low-cost options for meeting these statistical criteria are provided. Research laboratories who infrequently measure 25(OH)D are advised to repeat steps 1-4 for every measurement cycle. For users of commercial immunoassays who have relatively little control over standardization, we present an option for using trueness controls to develop a master equation that can be used to standardize results to the reference methods.

Download full-text PDF

Source
http://dx.doi.org/10.5740/jaoacint.17-0259DOI Listing

Publication Analysis

Top Keywords

reference measurement
8
statistical criteria
8
measurement systems
8
trueness controls
8
measurement
6
general steps
4
steps standardize
4
standardize laboratory
4
laboratory measurement
4
measurement serum
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!