A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of articular perforations of the proximal humerus fracture using a mobile 3D image intensifier - a cadaver study. | LitMetric

Background: The purpose of this study was to investigate the accuracy of perforation detection with multiplanar reconstructions using a mobile 3D image intensifier.

Methods: In 12 paired human humeri, K-wires perforating the subchondral bone and placed just below the cartilage level were directed toward five specific regions in the humeral head. Image acquisition was initiated by a fluoroscopy scan. Within a range of 90°, 45° external rotation (ER) and 45° internal rotation (IR). The number and percentage of detected perforating screws were grouped and analyzed. Furthermore, the fluoroscopic images were converted into multiplanar CT-like reconstructions. Each K-wire perforation was characterized as "detected" or "not detected".

Results: In the series of fluoroscopy images in the standard neutral position at 30° internal rotation, and 30° external rotation, the perforations of all K-wires (n = 56) were detected. Twenty-nine (51.8%) of them were detected in one AP view, 22 (39.3%) in two AP views, and five (8.9%) in three AP views. All K-wire perforations (100%, n = 56) were detected in multiplanar reconstructions.

Conclusion: In order to reveal all of the intraoperative and postoperative screw perforations in a "five screw configuration", conventional AP images should be established in both the neutral positions (0°), at 30° internal rotation and 30° external rotation. Alternatively, the intraoperative 3D scan with multiplanar reconstructions enables a 100% rate of detection of the screw perforations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5540431PMC
http://dx.doi.org/10.1186/s12880-017-0201-0DOI Listing

Publication Analysis

Top Keywords

external rotation
12
internal rotation
12
mobile image
8
multiplanar reconstructions
8
30° internal
8
rotation 30°
8
30° external
8
n = 56 detected
8
screw perforations
8
rotation
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!