Introduction: Diagnosis of Latent Tuberculosis Infection (LTBI) is difficult due to no clinical manifestations. Cases of LTBI are mostly sputum negative. The World Health Organization recommends the Tuberculin Skin Test (TST) as the current diagnostic standard for LTBI. Our previously developed serologic strip test for LTBI detection had suboptimal sensitivity. Additional (MTB) latency-associated antigens may improve the detection rate of LTBI.

Aim: The present study aimed to optimize sensitivity of existing strip test.

Materials And Methods: A combination of recombinant latency proteins Rv2029c, Rv2031c, Rv2032, Rv2627c, Rv3133c, and Rv3716c was used to prepare the strips and evaluate the performance with the sera of patients in four well-classified categories: LTBI, active pulmonary TB, healthy TB contacts and other non-TB diseases.

Results: A total of 91 serum samples from various clinical categories were screened with the strips. Among clinically diagnosed LTBI patients, strip test yielded a sensitivity of 75.0%. Among clinically diagnosed non-LTBI subjects, strip test yielded 88.1% specificity. The diagnostic positive and negative predictive values for strip test in reference to various clinical contexts were 77.4% and 86.7%, respectively.

Conclusion: Addition of the six potential latency proteins could improve the diagnostic performance of existing strip test for LTBI. The use of suitable immunodominant antigens could maximize sensitivity in the diagnosis and differentiate MTB infection status.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5535349PMC
http://dx.doi.org/10.7860/JCDR/2017/25860.9994DOI Listing

Publication Analysis

Top Keywords

strip test
24
latent tuberculosis
8
test ltbi
8
existing strip
8
latency proteins
8
clinically diagnosed
8
test yielded
8
strip
7
test
7
ltbi
7

Similar Publications

A novel fluorescence sensing nanoplatform (CDs/AuNCs@ZIF-8) encapsulating carbon dots (CDs) and gold nanoclusters (AuNCs) within a zeolitic imidazolate framework-8 (ZIF-8) was developed for ratiometric detection of formaldehyde (FA) in the medium of hydroxylamine hydrochloride (NHOH·HCl). The nanoplatform exhibited pink fluorescence due to the aggregation-induced emission (AIE) effect of AuNCs and the internal filtration effect (IFE) between AuNCs and CDs. Upon reaction between NHOH·HCl and FA, a Schiff base formed via aldehyde-diamine condensation, releasing hydrochloric acid.

View Article and Find Full Text PDF

Background: Secondhand smoke (SHS) exposure remains a critical public health concern, especially for adolescents, who are more susceptible to its harmful effects and may initiate smoking as a result. SHS, comprising both mainstream and sidestream smoke, contains over 7000 chemicals, many of which are carcinogenic. Adolescents exposed to SHS are more likely to experiment with smoking due to environmental influences, peer pressure, and familial smoking behavior.

View Article and Find Full Text PDF

Background And Aim: In animal husbandry, antibiotics are frequently used as growth promoters, as well as for illness prevention and treatment. They are considered important toxic and allergenic contaminants of food and a serious risk factor for the spread of antibiotic resistance. National and international regulatory authorities have established limits on the permissible residue of antibiotics in food.

View Article and Find Full Text PDF

A combined experimental-computational approach for retinal characterization.

Exp Eye Res

January 2025

Department of Chemistry, Materials and Chemical Engineering "Giulio Natta" (LaBS), Politecnico di Milano, Milano, Italy. Electronic address:

Subretinal injection of gene products is the only treatment option for inherited retinal diseases. However, this procedure induces localized high multiaxial deformations, potentially causing irreversible tissue damage due to retinal overstretching and tearing. Comprehensive characterization of retinal mechanical behavior is essential for performing safe injections.

View Article and Find Full Text PDF

MUA-modified Au nanocluster-driven fluorescence sensor for chromatographic test strips-based visual detection of patulin.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

Institute of Solid State Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; Key Laboratory of Photovoltaic and Energy Conservation Materials, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. Electronic address:

The relationship between human health and patulin (PAT) in the diet is a complex and intertwined one. The development of a sensing approach for the field detection of patulin is crucial, as the current approach lacks real-time detection capabilities and is costly in terms of material and technology. This paper presents a portable ratiometric fluorescence sensor that can be used to rapidly, accurately, and efficiently detect patulin in food items at the point of origin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!