Background: Rapid, accurate, and reproducible assessment of intravascular volume status is crucial in order to predict the efficacy of volume expansion in septic patients. The aim of this study was to verify the feasibility and usefulness of the internal jugular vein collapsibility index (IJV-CI) as an adjunct to the inferior vena cava collapsibility index (IVC-CI) to predict fluid responsiveness in spontaneously-breathing patients with sepsis.
Methods: Three stages of sonographic scanning were performed. Hemodynamic data were collected using the Ultrasonic Cardiac Output Monitor 1A system (Uscom, Ltd., Sydney, NSW, Australia) coupled with paired assessments of IVC-CI and IJV-CI at baseline, after passive leg raise (PLR), and again in semi-recumbent position. Fluid responsiveness was assessed according to changes in the cardiac index (CI) induced by PLR. Patients were retrospectively divided into 2 groups: fluid responder if an increase in CI (ΔCI) ≥15% was obtained after PLR maneuver, and non-responder if ΔCI was <15%.
Results: Total of 132 paired scans of IJV and IVC were completed in 44 patients who presented with sepsis and who were not receiving mechanical ventilation (mean age: 54.6±16.1 years). Of these, 23 (52.2%) were considered to be responders. Responders had higher IJV-CI and IVC-CI before PLR maneuver than non-responders (p<0.001). IJV-CI of more than 36% before PLR maneuver had 78% sensitivity and 85% specificity to predict responder. Furthermore, less time was needed to measure venous diameters for IJV-CI (30 seconds) compared with IVC-CI (77.5 seconds; p<0.001).
Conclusion: IJV-CI is a precise, easily acquired, non-invasive parameter of fluid responsiveness in patients with sepsis who are not mechanically ventilated, and it appears to be a reasonable adjunct to IVC-CI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5505/tjtes.2016.04832 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!