Background: Physical activity and exercise is central to conservative management of knee osteoarthritis (KOA), but is often difficult for patients with KOA to maintain over the decade or more prior to surgical management. Better approaches are needed for maintaining physical function and health in this population that can also address the patho-biomechanics of the osteoarthritic knee. The objective of the study is to quantify how a lower-extremity robotic exoskeleton (dermoskeleton) modifies the external knee moments during over-ground walking in a sample of healthy adults, and to evaluate these biomechanical modifications in the context of the osteoarthritic knee.
Method: Motion analysis data was acquired for 13 participants walking with and without the dermoskeleton. Force plate data, external knee moment arms, and knee moments in the laboratory and tibia frames of reference were computed, as well as time-distance parameters of walking, and compared between the two conditions.
Results: Although gait speed was not different, users took shorter and wider steps when walking with the dermoskeleton. Ground reaction forces and early-stance knee moment increased due to the added mass of the dermoskeleton, but the knee adduction moment was significantly reduced in late stance phase of gait. There was no effect on the knee torsional moment when measured in the anatomical frame of reference, and the late-stance knee flexion moment was invariant.
Conclusions: The dermoskeleton demonstrated favorable biomechanical modifications at the knee in healthy adults while walking. Studies are warranted to explore this technology for enabling physical activity-based interventions in patients with KOA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.knee.2017.04.004 | DOI Listing |
J Biomech Eng
January 2025
Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic, 2111 E. 96th Street, Cleveland, OH 44106.
To measure knee joint kinematics, coordinate systems (CS) must be assigned to the tibia and femur. Functional CS have been shown to be more reproducible than Anatomical. This study aims to quantify the benefits of using Functional CS in in vitro testing.
View Article and Find Full Text PDFJB JS Open Access
January 2025
School of Medicine, Rural Clinical School, University of Queensland, Toowoomba, Queensland, Australia.
Background: Although there is a known correlation between obesity and revision risk following total knee arthroplasty (TKA), there is an ongoing debate regarding the appropriateness of denying TKA solely based on the body mass index (BMI) of a patient. Our aim was to determine whether a patient's American Society of Anesthesiologists (ASA) class predicts their risks of early all-cause revision and revision for periprosthetic joint infection (PJI) following primary TKA, independent of their BMI.
Methods: Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) were obtained regarding all patients who underwent primary TKA for osteoarthritis in Australia from January 1, 2015, to December 31, 2022.
J Exp Orthop
January 2025
Department of Trauma Surgery, BG Trauma Center Tuebingen University of Tuebingen Tuebingen Germany.
Purpose: Malalignment of the lower extremity can affect one, two or all three anatomic planes. We hypothesized an influence between the malalignment of the coronal and axial planes.
Methods: A total of 356 lower extremities of 226 patients were included.
J Hip Preserv Surg
December 2024
Hip and Knee Adult Reconstruction Department, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra, Calzada México-Xochimilco No. 289 Colonia Arenal de Guadalupe Delegación, Tlalpan C.P., Ciudad de México 14389, México.
Femoroacetabular impingement syndrome (FAIS) is a common condition of the hip that can cause significant damage to the joint, leading to degeneration and osteoarthritis. FAIS constitutes an abnormal and dynamic contact between the femoral head-neck junction and the acetabular rim, resulting from altered bone morphology at one or both sites. Repetitive trauma at the site of impingement generates progressive damage to the acetabular labrum, chondrolabral junction, and articular cartilage.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
January 2025
Clinical Research Department, Sydney Knee Specialists, Kogarah, New South Wales, Australia.
Purpose: In functionally aligned (FA) total knee arthroplasty (TKA), femoral component rotation (FCR) is personalised to optimise flexion gap balance. As axial malalignment has been attributed to patellofemoral complications, this study assessed FA FCR in relation to the surgical transepicondylar axis (TEA) and early implant survivorship.
Methods: We analysed 446 robotic-assisted primary TKAs in 393 patients using FA with preresection gap balancing.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!