OBJECTIVE Minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has been adopted as an alternative technique to hasten recovery and minimize postoperative morbidity. Advances in instrumentation technologies and operative techniques have evolved to maximize patient outcomes as well as radiographic results. The development of expandable interbody devices allows a surgeon to perform MIS-TLIF with minimal tissue disruption. However, sagittal segmental and pelvic radiographic outcomes after MIS-TLIF with expandable interbody devices are not well characterized. The object of this study is to evaluate the radiographic sagittal lumbar segmental and pelvic parameter outcomes of MIS-TLIF performed using an expandable interbody device. METHODS A retrospective review of MIS-TLIFs performed between 2014 and 2016 at a high-volume center was performed. Radiographic measurements were performed on lateral radiographs before and after MIS-TLIF with static or expandable interbody devices. Radiographic measurements included disc height, foraminal height, fused disc angle, lumbar lordosis, pelvic incidence, sacral slope, and pelvic tilt. Mismatch between pelvic incidence and lumbar lordosis were calculated for each radiograph. RESULTS A total of 48 MIS-TLIFs were performed, predominantly at the L4-5 level, in 44 patients. MIS-TLIF with an expandable interbody device led to a greater and more sustained increase in disc height when compared with static interbody devices. Foraminal height increased after MIS-TLIF with expandable but not with static interbody devices. MIS-TLIF with expandable interbody devices increased index-level segmental lordosis more than with static interbody devices. The increase in segmental lordosis was sustained in the patients with expandable interbody devices but not in patients with static interbody devices. For patients with a collapsed disc space, MIS-TLIF with an expandable interbody device provided superior and longer-lasting increases in disc height, foraminal height, and index-level segmental lordosis than in comparison with patients with static interbody devices. Using an expandable interbody device improved the Oswestry Disability Index scores more than using a static interbody device, and both disc height and segmental lordosis were correlated with improved clinical outcome. Lumbar MIS-TLIF with expandable or static interbody devices had no effect on overall lumbar lordosis, pelvic parameters, or pelvic incidence-lumbar lordosis mismatch. CONCLUSIONS Performing MIS-TLIF with an expandable interbody device led to a greater and longer-lasting restoration of disc height, foraminal height, and index-level segmental lordosis than MIS-TLIF with a static interbody device, especially for patients with a collapsed disc space. However, neither technique had any effect on radiographic pelvic parameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2017.5.FOCUS17197 | DOI Listing |
Medicina (Kaunas)
December 2024
Division of Spine, Department of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore 308433, Singapore.
Spine surgery has undergone significant advancements, particularly with regard to robotic systems that enhance surgical techniques and improve patient outcomes. As these technologies become increasingly integrated into surgical practice, it is essential to evaluate their added value and cost savings. Hence, this study compared robot-assisted and navigation-based spine surgery, focusing on surgical efficiency.
View Article and Find Full Text PDFNeurospine
December 2024
Department of Orthopedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
This video presents a case of L4-5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root.
View Article and Find Full Text PDFNeurospine
December 2024
Morgenstern Institute of Spine, Centro Médico Teknon, Barcelona, Spain.
This article aims to introduce a novel full-endoscopic anterior cervical discectomy and fusion (ACDF) procedure to treat cervical myelopathy. Adoption of endoscopic anterior cervical procedures has been lagging due to safety concerns and the necessity of placing an interbody cage. We have developed novel instrumentation and a modified percutaneous anterior cervical approach that allows a safe and reproducible full-endoscopic ACDF.
View Article and Find Full Text PDFInt J Spine Surg
December 2024
Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland
Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopaedic Surgery, The Jikei University School of Medicine, 3-19-18 Nishi-shimbashi, Minato-ku, Tokyo, 105-8471, Japan.
Purpose: This study aimed to identify whether the ratio of the vertebral Hounsfield unit to serum pentosidine (H/P ratio), which reflects bone density and quality, can predict screw loosening after spinal fusion surgery.
Methods: A retrospective case-control study was conducted in 35 patients (mean age 71 ± 10.4 years, 18 men) who underwent spinal interbody fusion for lumbar spine disease between June 2020 and February 2022.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!