To reduce heavy metal leaching and stabilize municipal solid waste incineration (MSWI) fly ash, different methods and combination of methods were tested: water washing, electrodialytic separation and thermal treatment at 1000°C. A comparison of heavy metal concentration and leaching levels of As, Cr, Pb and Zn for the different untreated and treated ashes was made. The results showed that minimizing leaching to meet the limiting values of the all the studied heavy metals can be obtained at the same time by combining water washing, electrodialytic separation and thermal treatment. The ash subjected to this combination had lower Cr than the ash solely subjected to thermal treatment or subjected to water washing prior to thermal treatment. The electrodialytic separation (EDS) of the washed ash lowered pH from alkaline to acidic, which resulted in elevated leaching of Cd and Zn, while the Cr leaching was reduced. Up to 58.6% of Zn and 5.5% of Pb were extracted by EDS compared to less than 0.6% extraction by water washing. During thermal treatment of the EDS treated ash, the ash was re-alkalized. Due to solidification and possibly evaporation, most heavy elements left in the thermally treated ash were stabilized and immobilized. However, leaching of As and/or Cr was still problematic and did not meet the limit value for the thermally treated ash being recycled in construction work. The removal of Ca and decomposition of Ca oxides and minerals during EDS was linked to the leaching patterns of As and Cr after thermal treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wasman.2017.07.011DOI Listing

Publication Analysis

Top Keywords

thermal treatment
24
water washing
16
electrodialytic separation
12
treated ash
12
ash
10
mswi fly
8
fly ash
8
heavy metal
8
washing electrodialytic
8
separation thermal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!