The pulse amplitude ratio, the ratio of pulse pressure at the end of a Valsalva maneuver to before the onset of Valsalva, correlates with filling pressure. This study aimed to noninvasively estimate cardiac filling pressure in patients with heart failure. We developed a noninvasive handheld device to measure pulse amplitude ratio using finger photoplethysmography. In 69 patients who underwent right heart catheterization, photoplethysmography waveforms were recorded during a standardized Valsalva maneuver, and in 60 of these patients, pulse amplitude ratio was able to be calculated. Pulse amplitude ratio correlated with pulmonary capillary wedge pressure (PCWP) (r = 0.58, p <0.0001), particularly among those subjects with reduced ejection fraction (r = 0.60, p = 0.002, n = 25). A multivariable linear regression model for PCWP including pulse amplitude ratio, age, body mass index, systolic blood pressure, diastolic blood pressure, and heart rate yielded an R of 0.54. Difference in mean pulse amplitude ratio for subjects with a PCWP ≤15 mm Hg versus >15 mm Hg was statistically significant (p <0.0001, area under receiver operating characteristics curve 0.79 [0.66, 0.92]). Pulse amplitude ratio ≥0.55 predicted PCWP >15 mm Hg with 73% sensitivity and 77% specificity. Pulse amplitude ratio also increased by an average of 0.03 with a leg raise maneuver (p = 0.05, n = 36). In conclusion, we demonstrate that noninvasively measured response to the Valsalva maneuver in patients with HF can estimate PCWP and also detect changes within a single patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2017.06.029 | DOI Listing |
Ultrasonics
January 2025
Medical Ultrasound Department for the Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China. Electronic address:
Shear Wave Elastography (SWE) is an imaging technique that detects shear waves generated by tissue excited by Acoustic Radiation Force (ARF), and characterizes the mechanical properties of soft tissue by analyzing the propagation velocity of shear wave. ARF induces a change in energy density through the nonlinear propagation of ultrasound waves, which drives the tissue to generate shear waves. However, the amplitude of shear waves generated by ARF is weak, and the shear waves are strongly attenuated in vivo.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Faculty of Sciences, University of Coimbra, Palacio de las Escuelas 3004-531, Coimbra, 3004-504, PORTUGAL.
Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.
Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.
Sci Rep
January 2025
China Institute of Sport and Health Science, Beijing Sport University, Beijing, 100084, China.
This study explored the effects of training weight and amplitude in whole-body vibration (WBV) on exercise intensity, indicated by oxygen consumption (VO) and heart rate. In LOAD-study: ten participants performed squats under non-WBV and WBV (30 Hz 2 mm) conditions at 0%, 40%, and 80% bodyweight (BW). In AMPLITUDE-study: eight participants performed squats under non-WBV, low-amplitude WBV (30 Hz 2 mm), and high-amplitude WBV (30 Hz 4 mm) conditions with 0% and 40%BW.
View Article and Find Full Text PDFExpert Rev Med Devices
January 2025
Boston Scientific Neuromodulation, Valencia, California, USA.
Background: Fast-acting Sub-perception Therapy (FAST) is a novel spinal cord stimulation (SCS) modality delivering paresthesia-free pain relief. Our study evaluated the longer-term, real-world impact of FAST on chronic pain.
Research Design And Methods: As part of a multicenter, real-world, consecutive case series, we retrospectively identified patients who used FAST-SCS and analyzed their data.
Aquat Toxicol
January 2025
Center for the Development of Functional Materials (CDMF), Universidade Federal de São Carlos (UFSCar), Rodovia Washington Luís, Km 235 13565-905, São Carlos, SP, Brazil.
The semiconductor copper tungstate (CuWO) may end up in aquatic ecosystems since it has the potential for water decontamination. The toxic effects of CuWO are totally unknown for eukaryotic organisms. In view of this, we aimed to evaluate the toxicity of CuWO particles (size of 161.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!