Background: EUS-guided gastroenterostomy (EUS-GE) is a developing modality in the management of gastric outlet obstruction (GOO) with several technical approaches, including the direct and balloon-assisted techniques. The aim of this study was to compare the direct with the balloon-assisted modality while further defining the role of EUS-GE in GOO.
Methods: This multicenter, retrospective study involved consecutive patients who underwent EUS-GE with the direct or balloon-assisted technique for GOO (January 2014 to October 2016). The primary outcome was technical success. Secondary outcomes were success (ability to tolerate at least a full fluid diet), procedure time, and rate/severity of adverse events (AEs).
Results: A total of 74 patients (44.6% women; mean age 63.0 ± 11.7 years) underwent EUS-GE for GOO (direct gastroenterostomy, n = 52; balloon-assisted gastroenterostomy, n = 22). GOO was of malignant and benign etiology in 66.2% and 33.8% of patients, respectively. Technical success was achieved in 94.2% of the direct and 90.9% of the balloon-assisted approach (P = .63). Mean procedure time was shorter with the direct technique (35.7 ± 32.1 minutes vs 89.9 ± 33.3 minutes, P < .001). The clinical success rate was 92.3% for the direct technique and 90.9% for the balloon-assisted modality (P = 1.00), with a mean time to oral intake of 1.32 ± 2.76 days. The AE rate was 6.8% with only 1 severe AE noted. Rate of AEs, postprocedure length of stay, need for reintervention, and survival were similar between the 2 groups.
Conclusions: EUS-GE is effective and safe in the management of GOO. The direct technique may be the preferred method given its shorter procedure time when compared with the balloon-assisted approach. Prospective trials are needed to confirm these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2017.07.030 | DOI Listing |
J Clin Med
January 2025
Division of Gastroenterology and Hepatology, Center for Digestive Health, Virginia Mason, Franciscan Health, Seattle, WA 98101, USA.
Endoscopic management of benign pancreaticobiliary disorders encompasses a range of procedures designed to address complications in gallstone disease, choledocholithiasis, and pancreatic disorders. Acute cholecystitis is typically treated with cholecystectomy or percutaneous drainage (PT-GBD), but for high-risk or future surgical candidates, alternative decompression methods, such as endoscopic transpapillary gallbladder drainage (ETP-GBD), and endoscopic ultrasound (EUS)-guided gallbladder drainage (EUS-GBD), are effective. PT-GBD is associated with significant discomfort as well as variable adverse event rates.
View Article and Find Full Text PDFJ Gastroenterol Hepatol
December 2024
Institute for Digestive Research, Digestive Disease Center, Soonchunhyang University College of Medicine, Seoul, South Korea.
Background And Aim: The impact of different anti-thrombotic agents on patients with suspected small bowel bleeding (SSBB) who underwent balloon-assisted enteroscopy (DAE) is unclear. We aimed to examine the clinical effects and predictive factors of DAE based on the thromboembolic agents used.
Methods: We enrolled 399 patients with SSBB from a web-based DAE registry across 30 medical centers in South Korea.
World Neurosurg
December 2024
Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Electronic address:
Surg Neurol Int
September 2024
Department of Neurosurgery, Nara City Hospital, Nara, Japan.
J Radiol Prot
September 2024
Department of Endovascular Neurosurgery, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo 105-8470, Japan.
This study aimed to evaluate the radiation doses (peak skin dose (PSD) and bilateral lens dose) for each interventional neuroradiology procedure. A direct measurement system consisting of small radiophotoluminescence glass dosimeter chips and a dosimetry cap made of thin stretchable polyester was used for radiation dosimetry. The mean PSDs for each procedure were 1565 ± 590 mGy (simple technique coil embolization (STCE) cases), 1851 ± 825 mGy (balloon-assisted coil embolization (BACE) cases), 2583 ± 967 mGy (stent-assisted coil embolization (SACE) cases), 1690 ± 597 mGy (simple flow-diverter stenting (FDS) cases), and 2214 ± 726 mGy (FDS + coiling cases).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!