A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanical Modeling of a Keratoconic Cornea. | LitMetric

Mechanical Modeling of a Keratoconic Cornea.

Cornea

*Department of Ophthalmology, Regional Hospital Center of Metz-Thionville, Mercy Hospital, Metz, France; †Ophthalmology Department, University Hospital Center of Nancy Brabois, Nancy, France; ‡Clinical Research Department, Regional Hospital Center of Metz-Thionville, Mercy Hospital, Metz, France; and §Technological Universitary Institut, GMP Department, Lorraine University, Metz, France.

Published: October 2017

Purpose: We created a laboratory model of a cornea that was subjected to various pressures and thermal and mechanical factors to better understand the genesis of keratoconus deformation.

Methods: A steel base allowed for fixation of circular multilaminated patches of araldite (10 cm in diameter, 5 mm thick) in which the corneal anatomy was modeled. The model was plunged into a steam room (374°F/3 bars of pressure for 1 h) to ensure thermal homogeneity and was subjected to pressure using compressed air. Three models were assessed: a fault-free model with no lesion (model 1), and 2 models with a defect. The first of the defective models (model 2) had an external crack-type lesion (1 cm long; 1 mm deep). The second defective model (model 3) had one quarter thinned down using abrasive sandpaper (thickness reduced by 30%-40%).

Results: For model 1, which represented a healthy cornea, homogeneous modification was noted when examined under polarized light. In model 2, no excessive deformation was noticed, but there were stress lines at the edge of the lesion. Model 3 had a deformity, similar to keratoconic deformation.

Conclusions: Our findings suggest that the disease progresses under environmental stresses, but only when there is an initial defect, and especially when there is a thinning down defect. This thinning down defect may be induced by continual eye rubbing.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000001293DOI Listing

Publication Analysis

Top Keywords

model
10
lesion model
8
defect thinning
8
thinning defect
8
mechanical modeling
4
modeling keratoconic
4
keratoconic cornea
4
cornea purpose
4
purpose created
4
created laboratory
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!