A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Revision of a furosemide-loading vestibular-evoked myogenic potential protocol for detecting endolymphatic hydrops. | LitMetric

Objective: The presence of endolymphatic hydrops can be suggested by improving the amplitude of vestibular-evoked myogenic potential (VEMP) after furosemide administration (furosemide loading VEMP [FVEMP]). The authors aimed to determine a stimulation frequency and judgment criteria to ascertain whether a revised FVEMP protocol can be applied to clinical settings.

Methods: The study included 25 individuals with unilateral Meniere's disease (MD) and 11 normal healthy volunteers. Normalized amplitude of VEMP, using a tone burst sound at 250, 500, 700, 1000, 1500 and 2000 Hz, was measured before and after furosemide administration in the two groups. Improvement ratio (IR) of amplitude was calculated at each frequency.

Results: There were no significant differences in IR between the control group and the MD group at each frequency, except at 500 Hz. Receiver operating characteristic curve analysis revealed an IR cut-off value of 14.2% at 500 Hz, with a sensitivity of 0.706 and a specificity of 0.810.

Conclusions: The revised FVEMP protocol using a 500 Hz tone burst stimulus and normalized amplitudes was defined as positive when IR exceeded 14.2% or when a biphasic wave could be detected after furosemide administration in cases without a detectable biphasic wave before administration.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00016489.2017.1355565DOI Listing

Publication Analysis

Top Keywords

furosemide administration
12
vestibular-evoked myogenic
8
myogenic potential
8
endolymphatic hydrops
8
revised fvemp
8
fvemp protocol
8
tone burst
8
biphasic wave
8
revision furosemide-loading
4
furosemide-loading vestibular-evoked
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!