Robot-assisted radical prostatectomy (RARP) has enabled steady and stable surgical procedures due to both meticulous maneuvers and magnified, clear, 3-dimensional vision. Therefore, better surgical outcomes have been expected with RARP than with other surgical modalities. However, even in the RARP era, post-prostatectomy incontinence has a relatively high incidence as a bothersome complication. To overcome post-prostatectomy incontinence, it goes without saying that meticulous surgical procedures and creative surgical procedures, i.e., "Preservation", "Reconstruction", and "Reinforcement" of the anatomical structures of the pelvis, are most important. In addition, medication and appropriate pad usage might sometimes be helpful for patients with post-prostatectomy incontinence. However, patients who have 1) BMI > 26 kg/m, 2) prostate volume > 70 mL, 3) eGFR < 60 mL/min, or a 4) Charlson comorbidity index > 2 have a tendency to develop post-prostatectomy incontinence despite undergoing the same surgical procedures. It is important for patients who have a high risk for post-prostatectomy incontinence to be given information about delayed recovery of post-prostatectomy incontinence. Thus, not only the surgical procedures, but also a comprehensive approach, as mentioned above, are important for post-prostatectomy incontinence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597523PMC
http://dx.doi.org/10.5387/fms.2017-15DOI Listing

Publication Analysis

Top Keywords

post-prostatectomy incontinence
32
surgical procedures
20
comprehensive approach
8
post-prostatectomy
8
incontinence
8
robot-assisted radical
8
radical prostatectomy
8
surgical
7
procedures
5
approach post-prostatectomy
4

Similar Publications

Objectives: To evaluate the impact of radiation timing on artificial urinary sphincter (AUS) outcomes. AUS is the gold standard treatment for post-prostatectomy incontinence. Radiation history has been associated with worse outcomes, including higher rates of erosion and infection.

View Article and Find Full Text PDF

Late erosion of an Adjustable Transobturator Male System (ATOMS) device.

IJU Case Rep

January 2025

Department of Urology Bendigo Health Bendigo Victoria Australia.

Introduction: This report describes late erosion of an Adjustable Transobturator Male System device which was inserted for post-prostatectomy incontinence. The Adjustable Transobturator Male System device eroded the bulbar urethra 5 years post insertion, despite initial improvement of symptoms.

Case Presentation: Following an open radical retropubic prostatectomy, a 64 year-old male patient developed post-prostatectomy incontinence.

View Article and Find Full Text PDF

Introduction: Robot-assisted radical prostatectomy (RARP) is the treatment option for localized prostate cancer. It can lead to side effects like erectile dysfunction (ED) and post-prostatectomy urinary incontinence (PPUI). This study aimed to evaluate association between dyadic adjustment, PPUI and ED.

View Article and Find Full Text PDF

Background: Vesicourethral anastomosis stenosis (VUAS) is a well-known complication of prostate cancer treatments, observed in up to 26% of the cases after radical prostatectomy. Conservative management, with single or even repeated transurethral dilation or endoscopic incision of the stenosis, is successful in many cases, but up to 9% of patients are destined to fail after endoscopic treatment. In these cases, a revision of the vesicourethral anastomosis is necessary and can be realized with different surgical approaches.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!