Study Design: A retrospective study.

Objective: To assess the safety and efficacy of iliac crest defect reconstruction using Kirschner wire (K-wire)/polymethylmethacrylate (PMMA) versus traditional autologous rib graft reconstruction.

Summary Of Background Data: The iliac crest has been the preferred donor site for strut bone graft for various spinal fusion surgeries.

Methods: Seventy-three patients (44 males and 29 females; average age: 57.2 y) were divided into 2 groups: the rib group (35 patients) and the K-wire/PMMA group (38 patients). All operations involved anterior spinal interbody fusion. Patients were followed-up, on average, for 34.2 months using plain radiographs and both pain and cosmesis visual analog scales (VAS) to assess the clinical results after surgery.

Results: Almost all patients had pain VAS scores of ≤1 and grade 1 cosmesis VAS scores with no significant difference between the 2 groups in terms of either pain or cosmesis (P=1.00 and 0.505, respectively). In addition, few complications were noted in both groups. Radiographic complications in the rib group and the K-wire group numbered 4 (11%) and 2 (5%), respectively; however, did not significantly differ between the 2 groups (P=0.418). One case required intraoperative revision of the length of the K-wire and 1 case needed reoperation for iliac ring fracture and K-wire migration. An additional case required revision due to a bad fall.

Conclusions: K-wire and bone cement reconstruction is an effective and safe alternative method for large iliac bone defect repair when autologous rib graft is not available.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0000000000000254DOI Listing

Publication Analysis

Top Keywords

kirschner wire
8
bone cement
8
large iliac
8
iliac bone
8
strut bone
8
bone graft
8
iliac crest
8
autologous rib
8
rib graft
8
rib group
8

Similar Publications

Background: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires.

Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate the effectiveness and safety of lateral closing wedge osteotomy with tension-band wire fixation for correcting cubitus varus deformity in pediatric patients. The primary objective was to assess the bone union rate, functional outcomes, and potential complications associated with this surgical approach.

Methods: We conducted a retrospective review of 104 pediatric cases (ages 7-15) with post-traumatic cubitus varus deformity treated between January 2018 and December 2019 at the Pediatric Orthopedic Department.

View Article and Find Full Text PDF

Background: Management of the extensive soft tissue injuries remains a significant challenge in orthopedic and plastic reconstructive surgery. Since the thumb is responsible for 40% of the functions of the hand, saving and reconstructing a mangled thumb is essential for the patient's future.

Case Presentation: This case report describes the management of a severe occupational thumb injury in a 25-year-old white Persian male who sustained an occupational injury to his left thumb, resulting in extensive burn, crush injury to the distal and proximal phalanx, and severe soft tissue damage to the first metacarpal, thenar, and palmar areas.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Background: Cementless hip hemiarthroplasty is one of the options for the treatment of osteoporotic femoral neck fractures. Intraoperative periprosthetic femoral calcar fractures sometimes occur during the surgery, and the use of cerclage wiring to maintain the position and stability of the femoral stem and prevent the progression of the fracture. This study examines the outcomes of cerclage wiring to treat intraoperative periprosthetic calcar fractures in cementless hip hemiarthroplasty in osteoporotic femoral neck fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!