Background: This study evaluates the clinical, radiological, histological, and histomorphometric aspects of a fully synthetic biphasic calcium phosphate (BCP) (60% hydroxyapatite and 40% ß-tricalcium phosphate), used in a human maxillary sinus floor elevation (MSFE) procedure with 9- and 12-month healing time.
Methods: A unilateral MSFE procedure, using 100% BCP, was performed in two series of five patients with healing times of 9 and 12 months respectively. Clinical and radiological parameters were measured up to 5 years postoperatively. Biopsy retrieval was carried out during dental implants placement. Histology and histomorphometry were performed on 5-μm sections of undecalcified bone biopsies.
Results: The MSFE procedure with BCP showed uneventful healing in all cases. All dental implants appeared to be well osseointegrated after 3 months. Radiological evaluation showed less than 1 mm tissue height loss from MSFE to the 5-year follow-up examination. No signs of inflammation were detected on histological examination. Newly formed mineralized tissue was found cranially from the native bone. The BCP particles were surrounded by connective tissue, osteoid islands, and newly formed bone. Mineralized bone tissue was in intimate contact with the BCP particles. After 12 months, remnants of BCP were still present. The newly formed bone had a trabecular structure. Bone maturation was demonstrated by the presence of lamellar bone. Histomorphometric analysis showed at 9 and 12 months respectively an average vital bone volume/total volume of 35.2 and 28.2%, bone surface/total volume of 4.2 mm/mm and 8.3 mm/mm, trabecular thickness of 224.7 and 66.7 μm, osteoid volume/bone volume of 8.8 and 3.4%, osteoid surface/bone surface (OS/BS) of 42.4 and 8.2%, and osteoid thickness of 93.9 and 13.6 μm.
Conclusions: MFSE with BCP resulted in new bone formation within the augmented sinus floor and allowed the osseointegration of dental implants in both groups. From a histological and histomorphometric perspective, a 9-month healing time for this type of BCP may be the optimal time for placement of dental implants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5524657 | PMC |
http://dx.doi.org/10.1186/s40729-017-0099-x | DOI Listing |
Sci Rep
January 2025
Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
This study aims to evaluate and compare the usability and performance of mixed reality (MR) technology versus conventional methods for preoperative planning of patient-specific reconstruction plates for orbital fractures. A crossover study design was used to compare MR technology with conventional three-dimensional (3D) printing approaches in the planning of maxillofacial traumatology treatments. The primary focus was on user-friendliness and the accuracy of patient-specific reconstruction planning.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Department of Stomatology, China-Japan Union Hospital of Jilin University, Changchun 130033, China. Electronic address:
This study explored a novel modification method for porous polyetheretherketone (PEEK) implants using a biomimetic coating to achieve synergistic enhancement of vascularization and bone regeneration. Inspired by the natural extracellular matrix (ECM) structure (consists of growth factors and matrix proteins), a biomimetic dual-factor coating capable of releasing bone morphogenetic protein-2 (BMP-2) and fibronectin (FN) was coated on the surface of 3D-printed porous PEEK scaffolds using polydopamine (PDA) as a binder. Experiments conducted with MC3T3-E1 cells or HUVECs in co-culture with scaffolds revealed that the biomimetic coating not only synergically promoted cell migration, adhesion and proliferation, but also enhanced angiogenesis and osteogenic differentiation simultaneously in vivo.
View Article and Find Full Text PDFJ Stomatol Oral Maxillofac Surg
January 2025
School of Dentistry, Chonnam National University, Gwangju, Republic of Korea; Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:
Objective: Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.
Materials And Methods: Ten maxillary models with edentulous areas were created using CT and optical scan data.
J Mater Sci Mater Med
January 2025
Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.
View Article and Find Full Text PDFJ Periodontol
January 2025
Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.
Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.