Background: Assessment of color disc photograph (C-DP) is affected by image quality, which decreases the ability to detect glaucoma. High-dynamic-range (HDR) imaging provides a greater range of luminosity. Therefore, the objective of this study was to evaluate the capability of ophthalmology residents to detect glaucoma using HDR-concept disc photography (HDR-DP) compared to C-DP.

Design: Cross-sectional study.

Methods: Twenty subjects were classified by 3 glaucoma specialists as either glaucoma, glaucoma suspect, or control. All C-DPs were converted to HDR-DPs and randomly presented and assessed by 10 first-year ophthalmology residents. Sensitivity and specificity of glaucoma detection were compared.

Results: The mean ± SD of averaged retinal nerve fiber layer (RNFL) thickness was 74.0 ± 6.1 m, 100.2 ± 9.6 m, and 105.8 ± 17.2 m for glaucoma, glaucoma suspect, and controls, respectively. The diagnostic sensitivity of HDR-DP was higher than that of C-DP (87% versus 68%, mean difference: 19.0, 95% CI: 4.91 to 33.1; = 0.014). Regarding diagnostic specificity, HDR-DP and C-DP yielded 46% and 75% (mean difference: 29.0, 95% CI: 13.4 to 44.6; = 0.002).

Conclusions: HDR-DP statistically increased diagnostic sensitivity but not specificity. HDR-DP may be a screening tool for nonexpert ophthalmologists.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504951PMC
http://dx.doi.org/10.1155/2017/8209270DOI Listing

Publication Analysis

Top Keywords

ophthalmology residents
12
detect glaucoma
12
glaucoma
9
capability ophthalmology
8
residents detect
8
glaucoma high-dynamic-range
8
disc photography
8
glaucoma glaucoma
8
glaucoma suspect
8
sensitivity specificity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!