Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following the application of viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of the new lens contributed to the overall stabilization. The smooth surface of this lens was able to achieve an intraoperative view of good quality not only during vitrectomy but also during scleral buckling procedures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505614 | PMC |
http://dx.doi.org/10.2147/OPTH.S137346 | DOI Listing |
Rev Sci Instrum
November 2024
F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona, Spain.
The ITER equatorial visible and infrared Wide Angle Viewing System (WAVS) will play a major role in the protection of plasma facing components by providing surface temperature measurements of these components. It will also image the plasma emission in the visible range. The WAVS is composed of 15 lines of sight located in four Equatorial Ports (EPs) 3, 9, 12, and 17.
View Article and Find Full Text PDFEur J Ophthalmol
November 2024
Department of Retina and Vitreous, Narayana Nethralaya, Bengaluru, Karnataka, India.
Nanoscale
August 2024
Department of Mechatronics Engineering, Konkuk University Glocal Campus, 268 Chungwon-daero, Chungju-si 27478, Republic of Korea.
Organic Light Emitting Diodes (OLEDs) have emerged as popular screen advancements in digital appliances, thanks to their unique characteristics such as self-emitting ability, transparency, true dark tone, and flexibility. In comparison to liquid crystal displays, OLED displays offer superior performance. Moreover, OLEDs are also a promising option for illuminating purposes.
View Article and Find Full Text PDFInt J Clin Oncol
October 2024
Department of Neurosurgery, Graduate School of Medical Science, Kanazawa University, 13-1 Takara-Machi, Kanazawa, Ishikawa, 920-8641, Japan.
Nerves and blood vessels must be protected during brain tumor surgery, which has traditionally relied on microscopes. In the 2000s, endoscopes and related equipment were developed for neurosurgery. In this review, we aim to outline the role of endoscopes in brain tumor surgery and discuss the emerging use of exoscopes.
View Article and Find Full Text PDFOphthalmologica
October 2024
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
Introduction: The aim of this study was to compare the long-term outcomes of conventional scleral buckling (CSB), modified scleral buckling (MSB), and scleral encircling (SE) in the treatment of rhegmatogenous retinal detachment and identify factors influencing the outcomes.
Methods: This comparative, retrospective cohort study assigned patients to CSB, MSB, and SE groups. The follow-up was 12 months, and the reattachment rate, complication rate, visual acuity, number of newly discovered tears during surgery, and changes in diopters were compared among the three surgeries.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!