Background: The use of transcatheter aortic valve replacement (TAVR) is increasing worldwide. We present our 6-year experience using three-dimensional (3D) transesophageal echocardiography (TEE) and investigate whether different sizing methods of the aortic annulus lead to different prosthesis size that may impact outcome.

Methods: We investigated 262 patients who underwent TAVR and had 3D TEE data sets of the aortic annulus. We have used the area-derived diameter (D = 2(area/π)) and the circumference-derived diameter (D = Circumference/π) to size the prosthesis in separate populations in different time periods.

Results: The D method is correlated with lower incidence of paravalvular aortic regurgitation (PVAR; odds ratio = 0.44, 95% confidence interval, 0.23-0.85; P = .015). Other factors associated with PVAR were the cover index, area-mismatch index, and circumference-mismatch index. Retrospectively, for the purposes of the study, we used the Edwards-Sapien 3 Valve 3D sizing guide in all patients, to predict the hypothetical valve size with each method. In the whole population, the calculated D was higher in all cases (D = 23.4 ± 2.3 mm vs D = 22.9 ± 2.3 mm; P < .001). The two methods had good agreement in predicting the valve size (kappa = 0.600). In total, 192 (73.3%) patients were assigned for the same prosthesis size, whereas 70 (26.7%) would be eligible for a different size, of which 44 (16.7%) would definitely have had a different valve implanted.

Conclusion: Using the aortic annulus area or circumference to calculate the annular diameter provides different values. Comparing the two methods, a different prosthesis size could have been implanted in 26.7% of patients. In our series the use of circumference-derived diameter resulted in lower incidence of PVAR. The findings of this study may be independent of the imaging modality and may therefore also apply to computed tomography-based aortic annulus measurements, but this needs to be further investigated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2017.05.014DOI Listing

Publication Analysis

Top Keywords

aortic annulus
12
transcatheter aortic
8
aortic valve
8
valve replacement
8
valve sizing
8
aortic
6
valve
5
three-dimensional measurement
4
measurement aortic
4
annulus dimensions
4

Similar Publications

Background: The short-term and midterm impact of gender differences on transcatheter aortic valve implantation (TAVI) has been studied. However, the impact on long-term clinical outcomes remains unclear. The objective of the study was to investigate the impact of gender differences after TAVI on long-term clinical outcomes and structural valve deterioration (SVD).

View Article and Find Full Text PDF

Background: The management of Transcatheter Aortic Valve Implantation (TAVI) patients with a small aortic annulus (SAA) postures a substantial challenge, increasing the risk of patient- prosthesis mismatch (PPM) and overall mortality.

Aims: This study aimed to compare the hemodynamic and clinical outcomes of transcatheter balloon-expandable valve (BEV) versus transcatheter self-expandable valve (SEV) in SAA.

Methods: We conducted propensity score matching (PSM) of severe AS patients with SAA who underwent trans-femoral TAVR and enrolled to the Israeli TAVR registry between the years 2008 and 2023.

View Article and Find Full Text PDF

Background: With the rapid expansion of transcatheter aortic valve replacement (TAVR), TAVR valve explantation is also increasing. Nevertheless, previous reports on Lotus Edge valve explantation are limited to only two reports, none of which include intraoperative videos. Therefore, we report the case of an older adult who underwent a 2-year-old Lotus Edge valve explantation, after developing prosthetic valve endocarditis (PVE) and aortic annular abscess, with a strong indication for a TAVR explantation and surgical aortic valve replacement (AVR).

View Article and Find Full Text PDF

Recurrent strokes after transcatheter aortic valve replacement in an elderly patient with severe bicuspid aortic valve stenosis: a case report.

BMC Cardiovasc Disord

December 2024

Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, 100730, China.

Background: Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high-risk patients with symptomatic severe aortic valve stenosis (AS). Recently, its use has also been extended to low-risk patients, resulting in its increasing utilization in patients with bicuspid aortic valve (BAV). But as a serious post-TAVR complication, ischemic stroke was associated with a nearly 6-fold increased 30-day mortality.

View Article and Find Full Text PDF

Background: The precise etiology of hypoplasia of the posterior mitral valve leaflet (PMVL) remains incompletely elucidated; however, it has been hypothesized to stem from genetic mutations occurring during fetal development. Herein, we present the anatomical characteristics of the mitral valve and associated cardiac pathologies in patients with hypoplastic PMVL.

Methods: This single-center retrospective study involved patients who presented between 2015 and 2021 at a tertiary healthcare facility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!