In vitreoretinal surgery, membrane peeling is a prototypical task where a layer of fibrous tissue is delaminated off the retina with a micro-forceps by applying very fine forces that are mostly imperceptible to the surgeon. Previously we developed sensitized ophthalmic surgery tools based on fiber Bragg grating (FBG) strain sensors, which were shown to precisely detect forces at the instrument's tip in two degrees of freedom perpendicular to the tool axis. This paper presents a new design that employs an additional sensor to capture also the tensile force along the tool axis. The grasping functionality is provided via a compact motorized unit. To compute forces, we investigate two distinct fitting methods: a linear regression and a nonlinear fitting based on second-order Bernstein polynomials. We carry out experiments to test the repeatability of sensor outputs, calibrate the sensor and validate its performance. Results demonstrate sensor wavelength repeatability within 2 pm. Although the linear method provides sufficient accuracy in measuring transverse forces, in the axial direction it produces a root mean square (rms) error over 3 mN even for a confined magnitude and direction of forces. On the other hand, the nonlinear method provides a more consistent and accurate measurement of both the transverse and axial forces for the entire force range (0-25 mN). Validation including random samples shows that our tool with the nonlinear force computation method can predict 3-D forces with an rms error under 0.15 mN in the transverse plane and within 2 mN accuracy in the axial direction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5515300 | PMC |
http://dx.doi.org/10.1109/JSEN.2017.2694965 | DOI Listing |
Eur J Med Res
December 2024
Department of Anesthesiology and Reanimation, Faculty of Medicine, Osmangazi University, Büyükdere Mh, Odunpazarı, 26040, Eskişehir, Turkey.
Background: Ophthalmic procedures are increasingly being performed under regional anesthesia techniques such as peribulbar and incisionless sub-Tenon's blocks. The aim is to compare peribulbar block with incisionless sub-Tenon's block in terms of perioperative complications in patients who underwent cataract and vitreoretinal surgeries.
Methods: The patients who underwent cataract or vitroretinal surgery under peribulbar block or incisionless sub-Tenon's block were included in the study.
Arch Soc Esp Oftalmol (Engl Ed)
December 2024
Departamento de Oftalmología, Hospital Universitario Virgen de la Macarena, Sevilla, Spain; Miembros de la «Red de Enfermedades Inflamatorias, Enfermedades Inflamatorias Oculares, Enfermedades Inflamatorias No Infecciosas de la Superficie Ocular, Instituto de Salud Carlos III (RICORS). FISS-21-RD21/0002/0011»; Área de Oftalmología, Departamento de Cirugía, Universidad de Sevilla, Sevilla, Spain.
Although silicone oil is used as an intraocular buffer in vitreoretinal surgical procedures, its use can cause complications, including glaucoma. This study highlights the importance of individualized approaches for the management of silicone oil-induced glaucoma. A 62-year-old man with a past medical history of retinal detachment and multiple ocular surgical procedurespresented with uncontrolled ocular pressure peaks after retinal detachment surgery using silicone oil as a buffer, which did not resolve after removal of the buffer.
View Article and Find Full Text PDFIndian J Ophthalmol
December 2024
Department of Retina and Vitreous Services, Aravind Eye Hospital and Post Graduate Institute of Ophthalmology, Coimbatore, Tamil Nadu, India.
The pupillary direct and consensual reflex is an important non-invasive quick assessment of the neurological state of the eye. Currently, there is no cheap and affordable recording tool for screening and documentation of a relative afferent pupillary defect. We describe how to construct a frugal, do-it-yourself handheld scotopic binocular pupillometer device called Pupilmate.
View Article and Find Full Text PDFJ Vitreoretin Dis
December 2024
Retina Consultants of Minnesota, Minneapolis, MN, USA.
To understand the environmental burden associated with intravitreal injections (IVIs) and propose actionable solutions to mitigate this impact. An analysis of current IVI practices was conducted, focusing on packaging waste, energy consumption, the carbon footprint, and disposal processes. Data on the environmental footprint of IVIs were collected from the literature and industry reports.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Uveitis and Retina Services, L V Prasad Eye Institute, GMR Varalakshmi Campus, Visakhapatnam, Andhra Pradesh, India.
Purpose: To study clinical features, anatomical and visual outcomes in eyes having rhegmatogenous retinal detachment (RD) as the presenting feature of acute retinal necrosis (ARN).
Materials And Methods: We conducted a retrospective cohort study of patients with ARN (active/healed) and concomitant RD at the presenting visit.
Results: The median age of patients was 36 years, with a male preponderance (9:1).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!