A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Superparamagnetic graphene oxide-magnetite nanoparticle composites for uptake of actinide ions from mildly acidic feeds. | LitMetric

Super paramagnetic graphene oxide (GO) - FeO nanoparticle composites were prepared and characterized by conventional techniques such as XRD, SEM, EDX, FT-IR, Raman, XPS, DLS and zeta potential, etc. TEM studies have confirmed nanoparticle nature of the composites. The GO-magnetic nanoparticle composites can be dispersed in mildly acidic aqueous solutions and get concentrated in a small volume under application of an external magnetic field. The composites were evaluated for the uptake of actinide ions such as Am, UO, Th and Pu from mildly acidic aqueous solutions. Am sorption sharply increased with pH as the K values increased from about 10 at pH 1 to 10 at pH 3 beyond which a plateau in the K values was seen. Eu displayed nearly comparable uptake behaviour to that of Am while the uptake of other metal ions followed the trend: Pu(IV)>Th(IV)>>UO. The adsorption behaviour of Am onto the graphene oxide - FeO nanoparticle composites fitted very well to the Langmuir as well as Temkin isotherm models. The desorption rate (using 1M HNO) was fast and reusability study results were highly encouraging. The very high uptake values suggest possible application of the magnetic nanoparticles in radioactive waste remediation in natural ground water.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2017.07.008DOI Listing

Publication Analysis

Top Keywords

nanoparticle composites
16
mildly acidic
12
uptake actinide
8
actinide ions
8
ions mildly
8
graphene oxide
8
oxide feo
8
feo nanoparticle
8
acidic aqueous
8
aqueous solutions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!