Consultation Section: Refractive. June consultation #2.

J Cataract Refract Surg

São Paulo, Brazil.

Published: June 2017

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2017.06.011DOI Listing

Publication Analysis

Top Keywords

consultation refractive
4
refractive june
4
june consultation
4
consultation
2
june
1

Similar Publications

Background: The Eyhance Toric intraocular lens (IOL) builds upon the Tecnis Toric platform, initially associated with considerable post-operative rotational instability. Version 2, the Eyhance Toric IOL has been modified to enhance rotational stability. This study evaluates the post-operative rotational stability of the Eyhance Toric IOL compared to the Clareon Toric IOL, recognized for its stable performance.

View Article and Find Full Text PDF

Purpose: To compare the outcomes of two different surgical planning strategies for topography-guided repair of post-LASIK ectasia.

Methods: This is a case report of a patient presenting with post-LASIK ectasia. A retrospective chart review was used to collect details of the ophthalmic exam, as well as ocular imaging such as anterior segment optical coherence tomography and Scheimpflug corneal tomography.

View Article and Find Full Text PDF

An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, "advanced technology" IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.

View Article and Find Full Text PDF

: To report the role of prostaglandin-associated periorbitopathy (PAP) severity on the surgical efficacy of Ahmed Glaucoma Valve (AGV) implantation. : Retrospective observational case series. Participants were the consecutive 102 eyes from 102 Japanese subjects (55 males, 47 females; mean age ± standard deviation, 74.

View Article and Find Full Text PDF

Significance: Optimal meibography utilization and interpretation are hindered due to poor lid presentation, blurry images, or image artifacts and the challenges of applying clinical grading scales. These results, using the largest image dataset analyzed to date, demonstrate development of algorithms that provide standardized, real-time inference that addresses all of these limitations.

Purpose: This study aimed to develop and validate an algorithmic pipeline to automate and standardize meibomian gland absence assessment and interpretation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!