Purpose: To compare crystalline lens tilt in eyes before and intraocular lens (IOL) tilt in eyes after cataract surgery using swept-source optical coherence tomography (SS-OCT) (IOLMaster 700).
Setting: Hanusch Hospital, Vienna, Austria.
Design: Prospective case series.
Methods: Patients' eyes were scanned 1 week before and 2 months after cataract surgery with IOL implantation using an SS-OCT device. This device performs B-scans along 6 meridians (0, 30, 60, 90, 120, and 150 degrees) to determine lens and IOL tilt.
Results: Sixty-two eyes (62 patients) were included in the analysis. The mean magnitude and direction of tilt showed mirror symmetry between both eyes along the vertical axis and a primarily nasal outward tilt for right eyes and left eyes. The mean tilt was 4.3 degrees at 15.8 degrees preoperatively and 6.2 degrees at 16.8 degrees postoperatively. The mean direction of crystalline lens tilt preoperatively and IOL tilt postoperatively showed a strong correlation (R = 0.71), whereas the mean magnitude of tilt showed a weaker correlation (R = 0.37). The direction and magnitude of tilt of the crystalline lens and IOL eyes were normally distributed around similar values before and after surgery.
Conclusions: The correlations between crystalline lens tilt and IOL tilt using whole-eye scanning indicate that preoperative tilt determination using SS-OCT could help predict postoperative IOL tilt, assist in IOL (toric) power calculations, and potentially improve visual outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcrs.2017.01.026 | DOI Listing |
J Clin Med
December 2024
The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.
View Article and Find Full Text PDFPurpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.
Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).
Retina
January 2025
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Purpose: Anterior chamber air injection (ACAI) is a surgical technique used to decrease the occurrence of postoperative intraocular lens (IOL) haptic dislocation following phacovitrectomy with gas/air tamponade. The impact of this technique on IOL stability remains uncertain, prompting the design of this study to investigate further.
Methods: This study included 51 eyes of 51 patients who underwent phacovitrectomy with gas/air tamponade.
Eur J Ophthalmol
January 2025
Dept of Vitreoretinal Diseases, Sankara Nethralaya, Chennai, India.
Sci Rep
December 2024
Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!