A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Total and ionized magnesium testing in the surgical intensive care unit - Opportunities for improved laboratory and pharmacy utilization. | LitMetric

Purpose: Ionized fraction (iMg) is the physiologically active form of magnesium (Mg); total Mg may not accurately reflect iMg status. Erroneously "low" Mg levels may result in unnecessary repetitive testing.

Materials And Methods: From 11/2015 to 01/2016, patients ordered for Mg from a pilot ICU also had iMg tested. Weighted kappa statistic was used to assess agreement between Mg categories (low, normal, high). Predictors of unnecessary repeated Mg testing and repletion using data were explored through logistic regression models using GEE techniques to account for repeated measurements in both bivariate and multivariable analyses.

Results: There were 470Mg/iMg paired measurements from 173 patients. The weighted kappa statistic was 0.35 (95%CI 0.27-0.43) indicating poor agreement in assessment of magnesium status. Of the 34Mg samples reported as "low", only 6 (18%) were considered "low" using concurrent iMg testing. In the multivariable models, history of atrial fibrillation (aOR=1.61, 95%CI 1.16-2.21, p=0.004) and concomitant metoclopramide (aOR=1.71, 95%CI 1.03-2.81, p=0.036) were significant predictors of unnecessary repeat Mg testing.

Conclusions: In the surgical ICU, categorical agreement (low, normal, high) was poor between Mg and iMg. Over 80% of "low" total Mg values are erroneous and may result in unnecessary additional measurements and repletion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrc.2017.07.026DOI Listing

Publication Analysis

Top Keywords

result unnecessary
8
weighted kappa
8
kappa statistic
8
low normal
8
normal high
8
predictors unnecessary
8
img
5
total ionized
4
ionized magnesium
4
magnesium testing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!