Purpose: To assess the correlation between corneal biomechanical stiffness and refractive error (RE) in the pediatric population.

Methods: A total of 733 pediatric eyes were included in the study retrospectively. All eyes underwent corneal tomography (Pentacam), RE assessment, and air-puff deformation (Corvis-ST). Waveform analyses of deformation provided corneal stiffness (CS) and extraocular tissue stiffness (EOS). Eyes were subgrouped into emmetropia [manifest refraction spherical equivalent (MRSE) ∼ 0 D], hyperopia (MRSE > 0 D), myopia I (MRSE between 0 D and -3 D), myopia II (MRSE between -3 D and -6 D), and myopia III (MRSE greater than -6 D) for multivariate analyses. Ocular biometry variables [age, intraocular pressure (IOP), central corneal thickness (CCT), corneal astigmatism, anterior chamber depth, and RE] were used as covariates. The apparent elastic modulus (E) was defined as the ratio of CS and CCT.

Results: All groups had similar age, CCT, and IOP (P > 0.05). CS was the only parameter to differ between all the grades of myopia (P < 0.0001). CS was lower by 3.72%, 6.84%, and 10.68% in myopia I, II, and III eyes, respectively, relative to emmetropic eyes. EOS increased by 11.15%, 22.60%, and 28.5%, respectively. Multivariate regression revealed age, IOP, CCT, corneal astigmatism, anterior chamber depth, and RE as significant predictors of CS, with a high coefficient of regression (R = 0.66). Corneal E negatively correlated with the grade of myopia.

Conclusions: CS and EOS correlated negatively and positively with the grade of myopia, respectively. Ocular biometry variables were significant predictors of both CS and EOS. The decrease in CS was attributed to that in elastic modulus.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000001290DOI Listing

Publication Analysis

Top Keywords

ocular biometry
12
mrse myopia
12
correlation corneal
8
corneal biomechanical
8
biomechanical stiffness
8
stiffness refractive
8
refractive error
8
myopia mrse
8
myopia iii
8
biometry variables
8

Similar Publications

Objective: The study aimed to evaluate the interocular symmetry of macular sublayer thickness among healthy children aged 6-12 years.

Methods: The Shiraz Pediatric Eye Study included 500 randomly selected children who underwent SD-OCT of the macula and optical biometry using the IOLMaster-500. Exclusion criteria involved ocular abnormalities or axial lengths outside the 21.

View Article and Find Full Text PDF

Purpose: To apply a new method, the Taylor Diagram, and a new concept, the centered root mean square error (cRMSE), in evaluating the performance of IOL formulas.

Methods: The preoperative biometrics were measured with the IOLMaster 700 (Carl Zeiss Meditec) and the postoperative spherical equivalent refraction (SER) was calculated in 888 anonymous patients. The Taylor Diagram was applied to visualize the centered root mean square error (cRMSE) and the correlation coefficient between the predictions and the observations (R).

View Article and Find Full Text PDF

Influence of lens thickness on the accommodative range in healthy eyes.

J Optom

January 2025

Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium; Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium. Electronic address:

Background: The maximum accommodative range is a useful indication of visual function. It decreases with age, but the exact cause of this decrease is not fully understood. It is associated with the increasing rigidity of the lens and changes to the lens shape, as well as the geometry of the zonular attachments.

View Article and Find Full Text PDF

Objective: This study investigates the refractive accuracy of eight intraocular lens (IOL) power calculation formulas in patients with postoperative refractive surprise after phacoemulsification. It aims to determine if a different formula could result in better refractive outcomes in these eyes.

Methods And Analysis: We retrospectively reviewed consecutive patients undergoing uncomplicated phacoemulsification as a sole procedure between March 2007 and September 2020 at the University of Washington by glaucoma subspecialists as part of a study investigating cataract surgery in normal eyes.

View Article and Find Full Text PDF

Associations between choroidal thickness and rate of axial elongation in orthokeratology lens users.

Photodiagnosis Photodyn Ther

December 2024

Joint Shantou International Eye Center of Shantou University and The Chinese, University of Hong Kong, Shantou, Guangdong 515041, China. Electronic address:

Objective: To investigate the impact of using orthokeratology lenses (OK lenses) for one year on the axial length (AL) and choroidal thickness (ChT) in the 6 mm concentric central retinal region.

Methods: 36 myopic children (36 eyes) aged 8 to 16 years were enrolled. For the duration of one year, the OK group (18 subjects) utilized OK lenses, while the spectacles group (18 subjects) utilized single-vision spectacles as a control.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!