Purpose: The appropriate cosyntropin dose during cosyntropin stimulation tests remains uncertain. We conducted a prospective, randomized pilot study to compare 1 μg IV low dose cosyntropin test, 25 μg IM medium dose cosyntropin test, and 250 μg IM standard dose cosyntropin test to evaluate secondary adrenal insufficiency. Insulin tolerance test was used as the gold standard.
Method: The study included patients with hypothalamic/pituitary disease (n = 10) with at least one pituitary axis deficiency other than ACTH deficiency and controls (n = 12). All tests were done in random order. Sensitivity and specificity were calculated for total cortisol and serum free cortisol cut-off levels during cosyntropin stimulation tests.
Results: The median (range) age and F/M sex ratios for patients and controls were 54 years (23-62), 2/8, and 33 years (21-51), 6/6, respectively. The best total cortisol cut-off during low dose cosyntropin test, medium dose cosyntropin test, 30 min and 60 min standard dose cosyntropin test were 14.6 μg/dL (100% sensitivity & specificity), 18.7 μg/dL (100% sensitivity, 88% specificity), 16.1 (100% sensitivity & specificity), and 19.5 μg/dL (100% sensitivity & specificity), respectively. There was no difference in the ROC curve for cortisol values between the cosyntropin stimulation tests (p > 0.41). Using a cortisol cut-off of 18 μg/dL during cosyntropin stimulation tests, only cortisol level at 30 min during standard dose cosyntropin test provided discrimination similar to insulin tolerance test. The best peak free cortisol cut-off levels were 1 μg/dL for insulin tolerance test, 0.9 μg/dL for low dose cosyntropin test, 0.9 μg/dL for medium dose cosyntropin test, and 0.9 μg/dL and 1.3 μg/dL for 30 min and 60 min standard dose cosyntropin test, respectively.
Conclusion: All cosyntropin stimulation tests had excellent correlations with insulin tolerance test, when appropriate cut-offs were used. This pilot study does not suggest an advantage in using 25 μg cosyntropin dose during the cosyntropin stimulation test. A serum free cortisol cut-off of 0.9 μg/dL may be used as pass criterion during low dose cosyntropin test, standard dose cosyntropin test cosyntropin test, and 30 min standard dose cosyntropin test.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12020-017-1371-9 | DOI Listing |
BMJ Open
December 2024
Clinical Medicine, School of Medicine and Population Health, The University of Sheffield, Sheffield, UK
Introduction: Cortisol is an essential stress hormone and failure of its production, known as adrenal insufficiency (AI), is associated with significant mortality due to adrenal crisis. The Short Synacthen Test (SST) is the current diagnostic test of choice for AI, but it is both invasive and resource intensive. Globally, there is an unmet need for a non-invasive, cost-effective test.
View Article and Find Full Text PDFIntroduction: Consensus regarding the diagnostic cutoff values for cortisol responses to low-dose Cosyntropin testing (LDT) and its specific advantages over standard (high) dose test (HDT) in assessing the pituitary-adrenal axis in children is lacking.
Methods: In a retrospective study, patients who underwent sequential LDT and HDT were classified into two groups depending on the reason for testing: prolonged systemic glucocorticoid exposure (Group 1) or suspected hypothalamic-pituitary dysfunction (Group 2). Sensitivity and specificity analysis of varying cortisol levels during LDT in diagnosing ACTH deficiency (ACTHD) were calculated via the receiver operating characteristic curve (ROC) analysis against the reference diagnostic test HDT.
Endocrinol Diabetes Metab
September 2024
Department of Endocrinology & Diabetes, St Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia.
Background: Adrenal vein sampling (AVS), integral to identifying surgically remediable unilateral primary aldosteronism (PA), is technically challenging and subject to fluctuations in cortisol and aldosterone secretion. Intra-procedural adrenocorticotropic hormone (ACTH), conventionally administered as a 250-μg bolus and/or 50 μg per hour infusion, increases cortisol and aldosterone secretion and can improve AVS success, but may cause discordant lateralisation compared to unstimulated AVS.
Aims: To assess if AVS performed with ultra-low dose ACTH infusion causes discordant lateralisation.
Domest Anim Endocrinol
October 2024
Veterinary Sciences Post-Graduation Program (PPGCV), Veterinary Faculty, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Brazil; Animal Medicine Departament, Veterinary Faculty, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Brazil. Electronic address:
Porcine adrenocorticotrophic hormone (ACTH) has been considered valid for the ACTH stimulation test (ACTHST) in humans and dogs; however, its safety and efficacy for use in cats are unknown. Also, the equivalence between 5 µg/kg and 125 µg/cat dose of synthetic corticotropin (1-24 ACTH - cosyntropin/tetracosactide) is assumed for ACTHST in cats. This study evaluated the safety and effectiveness of different porcine recombinant ACTH doses for the ACTHST in healthy cats and its equivalence with tetracosactide.
View Article and Find Full Text PDFClin Transl Sci
August 2024
Mineralys Therapeutics, Radnor, Pennsylvania, USA.
Dysregulation of the mineralocorticoid hormone aldosterone is an increasingly prevalent cause of hypertension. Aldosterone synthase (CYP11B2) shares 93% homology to 11β-hydroxylase (CYP11B1), which produces cortisol. Lorundrostat, a highly selective inhibitor of CYP11B2, is a potential safe and effective treatment for aldosterone-dependent, uncontrolled hypertension, including treatment-resistant hypertension.