This case study examined how two rowers adapted their rowing patterns following crew training as a newly formed coxless pair. The two participants were expert (double-oar) single scull-boat rowers. Performing as a crew in the coxless-pair's sweep-boat, where each rower operates a single oar, on-the-water data were collected before and after a 6-week intensive team-training program. Rowing patterns were characterized by the horizontal oar angle, oar angular velocity and linear oar-water velocity profiles during the catch (minimal oar angle) to finish (maximal oar angle) half-cycles of the propulsive water phase. After crew training, rowers demonstrated a tighter synchronization and a closer correspondence in oar angle at the moment of catch, together with a closer matching of the evolution over time of their subsequent oar movements. Most likely due to the inherent asymmetries involved in sweep-boat rowing, the stroke rower also developed a somewhat longer-duration larger-amplitude oar movement than the bow rower. Remarkably, both rowers revealed changes in the inter-cycle variability of their individual patterns of rowing. While the initially more variable stroke rower improved the consistency of his rowing pattern over practice, the initially highly consistent bow rower on the contrary relaxed his tendency to always perform in the same way. We discuss how the crew performance changed over training and to what extent it was associated with changes in individual behaviors. Along the way we demonstrate that the often-used measure of average continuous relative phase does not adequately capture the particularities of the coordination pattern observed. Overall, the results obtained at the individual level of analysis suggest that team benefits were obtained through distinct adaptations of the rowers' individual rowing patterns.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498552 | PMC |
http://dx.doi.org/10.3389/fpsyg.2017.01139 | DOI Listing |
Purpose: LATTICE, a form of spatially fractionated radiation therapy that delivers high-dose peaks and low-dose valleys within the target, has been clinically utilized for treating bulky tumors. However, its application to small-to-medium-sized target remains challenging due to beam size limitations. To address this challenge, this work proposes a novel proton LATTICE (pLATTICE) modality using minibeams, namely minibeam-pLATTICE, that extends LATTICE approach for small-to-medium targets.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
January 2025
Department of Radiation Oncology, University of Florida College of Medicine, Jacksonville, Florida.
Radiation therapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs at risk (OARs) poses challenges to conventional radiation therapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.
View Article and Find Full Text PDFArXiv
November 2024
Department of Radiation Oncology, University of Kansas Medical Center, USA.
Objective: Proton spot-scanning arc therapy (ARC) is an emerging modality that can improve the high-dose conformity to targets compared with standard intensity-modulated proton therapy (IMPT). However, the efficient treatment delivery of ARC is challenging due to the required frequent energy changes during the continuous gantry rotation. This work proposes a novel method that delivers a multiple IMPT (multi-IMPT) plan that is equivalent to ARC in terms of biologically effective dose (BED).
View Article and Find Full Text PDFIn Vivo
October 2024
Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan.
Background/aim: This study aimed to compare the use of a rotating gantry in liver tumor carbon-ion radiotherapy using of a fixed-port for treatment planning.
Materials And Methods: Thirty patients with liver tumors were analyzed. Three treatment plans were developed for each case: one with a rotating gantry with a 360° angle, one with fixed ports of 0° and 90° with a ±20° couch rolling setting, and one with fixed ports of 45° and 90° with a ±20° couch rolling setting.
Phys Med Biol
October 2024
Department of Radiation Oncology, University of Kansas Medical Center, Kansas, United States of America.
LATTICE, a spatially fractionated radiation therapy (SFRT) modality, is a 3D generalization of GRID and delivers highly modulated peak-valley spatial dose distribution to tumor targets, characterized by peak-to-valley dose ratio (PVDR). Proton LATTICE is highly desirable, because of the potential synergy of the benefit from protons compared to photons, and the benefit from LATTICE compared to GRID. Proton LATTICE using standard proton RT via intensity modulated proton therapy (IMPT) (with a few beam angles) can be problematic with poor target dose coverage and high dose spill to organs-at-risk (OAR).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!