AI Article Synopsis

  • The ankle-brachial index (ABI) is not effective for identifying early-stage atherosclerosis, which is crucial for preventing functional decline in patients.
  • Researchers analyzed data from 1,103 participants to examine the link between femoral artery atherosclerosis and physical functioning, finding that higher intima media thickness and plaque presence were associated with lower performance scores, even in those with a normal ABI.
  • The study highlights the importance of assessing femoral artery atherosclerosis in individuals with a normal ABI, particularly those at higher risk, to facilitate earlier interventions that could enhance their quality of life.

Article Abstract

Background: The ankle-brachial index (ABI) is inadequate to detect early-stage atherosclerotic disease, when interventions to prevent functional decline may be the most effective. We determined associations of femoral artery atherosclerosis with physical functioning, across the spectrum of the ABI, and within the normal ABI range.

Methods And Results: In 2007-2011, 1103 multiethnic men and women participated in the San Diego Population Study, and completed all components of the summary performance score. Using Doppler ultrasound, superficial and common femoral intima media thickness and plaques were ascertained. Logistic regression was used to assess associations of femoral atherosclerosis with the summary performance score and its individual components. Models were adjusted for demographics, lifestyle factors, comorbidities, lipids, and kidney function. In adjusted models, among participants with a normal-range ABI (1.00-1.30), the highest tertile of superficial intima media thickness was associated with lower odds of a perfect summary performance score of 12 (odds ratio=0.56 [0.36, 0.87], =0.009), and lower odds of a 4-m walk score of 4 (0.34 [0.16, 0.73], =0.006) and chair rise score of 4 (0.56 [0.34, 0.94], =0.03). Plaque presence (0.53 [0.29, 0.99], =0.04) and greater total plaque burden (0.61 [0.43, 0.87], =0.006) were associated with worse 4-m walk performance in the normal-range ABI group. Higher superficial intima media thickness was associated with lower summary performance score in all individuals (=0.02).

Conclusions: Findings suggest that use of femoral artery atherosclerosis measures may be effective in individuals with a normal-range ABI, especially, for example, those with diabetes mellitus or a family history of peripheral artery disease, when detection can lead to earlier intervention to prevent functional declines and improve quality of life.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5586297PMC
http://dx.doi.org/10.1161/JAHA.117.005777DOI Listing

Publication Analysis

Top Keywords

summary performance
16
performance score
16
femoral artery
12
artery atherosclerosis
12
intima media
12
media thickness
12
normal-range abi
12
san diego
8
diego population
8
population study
8

Similar Publications

Trehalose has neuroprotective effects in neurodegenerative diseases. This study aimed to explore the impact of trehalose on traumatic brain injury (TBI) by investigating its role in neuroprotection. The TBI mice model was established utilizing the cortical impact technique followed by trehalose treatment.

View Article and Find Full Text PDF

Background: A decline in skeletal muscle mass and function known as skeletal muscle sarcopenia is an inevitable consequence of aging. Sarcopenia is a major cause of decreased muscle strength, physical frailty and increased muscle fatigability, contributing significantly to an increased risk of physical disability and functional dependence among the elderly. There remains a significant need for a novel therapy that can improve sarcopenia and related problems in aging.

View Article and Find Full Text PDF

Short-wave infrared (SWIR) imaging has a wide range of applications in civil and military fields. Over the past two decades, significant efforts have been devoted to developing high-resolution, high-sensitivity, and cost-effective SWIR sensors covering the spectral range from 0.9 μm to 3 μm.

View Article and Find Full Text PDF

Recent Advancements in Localization Technologies for Wireless Capsule Endoscopy: A Technical Review.

Sensors (Basel)

January 2025

Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC 3800, Australia.

Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body.

View Article and Find Full Text PDF

: Fructus (AOF) is a medicinal and edible resource that holds potential to ameliorate hyperuricemia (HUA), yet its mechanism of action warrants further investigation. : We performed network pharmacology, molecular docking, molecular dynamics simulation, and in vitro experiments to investigate the potential action and mechanism of AOF against HUA. : The results indicate that 48 potential anti-HUA targets for 4 components derived from AOF were excavated and predicted through public databases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!