Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We report a novel microfluidic technique for sampling of aerosols into liquids. The two-phase fluid, sampling air and collecting liquid, forms a stratified flow in the curved microchannel. By passing fluids through the curved region, the particles are transferred from air into the liquid phase by the particle centrifugal and drag forces. This microfluidic-based aerosol-into-liquid sampling system, called the MicroSampler, is driven by particle inertial differences. To evaluate the physical particle collection efficiency of the MicroSampler, we used standard polystyrene-latex (PSL) particles ranging in size from 0.6 to 2.1 μm and measured particle concentrations upstream and downstream of the MicroSampler with an aerodynamic particle sizer. The cutoff diameter of particle collection was selected controlling the air flow velocity (microfluidic air flow of 0.6 L/min showed a particle collection efficiency of ∼98% at a particle diameter of 1 μm), and continuous enriched particle sampling was possible for real-time postprocessing application. With regard to biological collection efficiency, the MicroSampler showed superior microbial recovery (Staphylococcus epidermidis) compared to the conventional BioSampler technique. These results indicate that our MicroSampler can be used as a portable, cost-effective, simple, and continuous airborne microorganism collector for applications in real-time bioaerosol detection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acssensors.6b00753 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!