Diurnal variation and repeatability of arterial stiffness and cardiac output measurements in the third trimester of uncomplicated pregnancy.

J Hypertens

aUniversity Hospitals of Leicester bDepartment of Obstetrics and Gynaecology, Health Sciences Division, University of Leicester, Leicester cDepartment of Cardiovascular Sciences and NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester dSt George's University of London, and St Georges University Hospitals NHS Foundation Trust. Molecular and Clinical Sciences Research Institute, London eDiabetes Research Centre and NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK.

Published: December 2017

Aim: To investigate same day repeated measures and diurnal variation of arterial stiffness, cardiac output (CO), stroke volume (SV) and total peripheral resistance (TPR) during the third trimester of normal pregnancy.

Methodology: Pulse wave velocity (PWV) and augmentation index (AIx) were recorded using the Arteriograph, while CO, SV and TPR were recorded using noninvasive cardiac output monitoring. The measurements were obtained in the third trimester of pregnancy from 21 healthy pregnant women at four time points (morning, afternoon, evening and midnight) over a 24-h period. Triplicate measurements of 67 women were obtained at 5-min intervals to assess repeatability between measurements within a patient.

Results: Diurnal measurements of arterial stiffness for brachial AIx, aortic AIx and PWV were not statistically significantly different at any of the four time points. Estimated means (SD) for PWV at the four stated time points were 7.81 (2.05), 8.45 (1.68), 7.87 (1.74) and 7.64 m/s (1.15), respectively (P = 0.267). Estimates for AIx at those time points were 10.22 (15.62), 4.44 (10.07), 6.49 (10.92) and 8.40% (8.16), respectively (P = 0.295). Similarly, mean arterial pressure, SV, SV index and TPR did not show any evidence of diurnal variation. However, we observed that the mean CO, cardiac index (CI) and heart rate (HR) varied from morning to midnight; the mean CO, HR and CI increased significantly in the afternoon compared with the corresponding mean morning measurements in a similar fashion to HR. Mean (SD) CO estimates at the four stated time points were 5.90 (1.33), 6.38 (1.49), 6.18 (1.43) and 5.80 ml/min (1.19), respectively, (P < 0.001), whereas mean CI estimates were 3.65 (0.58), 3.93 (0.68), 3.81 (0.65), and 3.57 (0.48), respectively, (P < 0.001), and mean HR estimates were 95 (12), 98 (13), 95 (12) and 88 (12.98), respectively (P < 0.001). Triplicate measurements of 61 women in our repeatability study showed moderate-to-high correlation between observations on the same woman for all Arteriograph and noninvasive cardiac output monitoring variables (estimates of intraclass correlation ranged from 0.49 to 0.91).

Conclusion: With the exception of CO, CI and HR which showed a diurnal variation, measurements of most haemodynamic parameters did not change significantly from morning to midnight, suggesting there was no evidence of systematic differences in the mean values of these variables at these time points. Multiple consecutive noninvasive measurements of vascular stiffness, CO, SV and TPR were highly correlated confirming repeatability of measurements in the third trimester of uncomplicated pregnancy, so these haemodynamic measurements do not need to be undertaken at a specific time period of the day.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HJH.0000000000001482DOI Listing

Publication Analysis

Top Keywords

time points
20
diurnal variation
12
arterial stiffness
12
cardiac output
12
third trimester
12
stiffness cardiac
8
measurements third
8
stated time
8
measurements
6
time
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!