Background: Forearm immobilization techniques are commonly used to manage distal radius, scaphoid, and metacarpal fractures. The purpose of our study was to compare the degree of rotational immobilization provided by a sugar-tong splint (STS), short arm cast (SAC), Munster cast (MC), and long arm cast (LAC) at the level of the distal radioulnar joint (DRUJ), carpus, and metacarpals.
Methods: Seven cadaveric upper extremity specimens were mounted to a custom jig with the ulnohumeral joint fixated in 90° of flexion. Supination and pronation were unrestricted. K-wires were placed in the distal radius, scaphoid, and metacarpals using fluoroscopic guidance to measure the total arc of rotation referenced to the ulnar ex-fix pin. Baseline measurements followed by sequential immobilization with well-molded STS, SAC, MC, and LAC were obtained with 1.25, 2.5, and 3.75 ft-lb of supination and pronation force directed through the metacarpal K-wire. Each condition was tested 3 times. Digital photographs were taken perpendicular to the ulnar axis to analyze the total arc of motion.
Results: The most effective constructs from least to greatest allowed rotational arcs were LAC, MC, SAC, and STS. Above-elbow constructs (MC, LAC) demonstrated superior immobilization compared with below-elbow constructs (SAC) ( P < .001). Circumferential constructs (SAC, MC, LAC) were superior to the noncircumferential construct (STS) ( P < .001). There were no significant differences between the MC and LAC in all conditions tested.
Conclusions: Both circumferential and proximally extended immobilization independently improved rotational control of the wrist. However, extending immobilization proximal to the epicondyles did not confer additional stability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5950959 | PMC |
http://dx.doi.org/10.1177/1558944717691129 | DOI Listing |
J Educ Health Promot
December 2024
Master in Biostatistics, Nursing Care Research Center, Iran University of Medical Sciences, Tehran, Iran.
Background: Non-pharmaceutical method is one of the conventional methods of reducing labor pain. Acupressure is suggested as an effective method for reducing labor pain with favorable effects on the outcome of childbirth. Different acupressure methods are suggested for this purpose; the most effective one has to be investigated.
View Article and Find Full Text PDFIran J Basic Med Sci
January 2025
Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
Objectives: Trans-sodium crocetinate (TSC) is one of the crocetin derivations that is more soluble and stable than crocetin and its cis form. It easily crosses the blood-brain barrier. TSC has neuroprotective effects.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea.
Background: To achieve successful anatomic rotator cuff repair with minimal tension, both the tear pattern and tear size should be considered. However, little information is available concerning the frequency of tear patterns and their effects on tendon healing.
Purpose: To evaluate the distribution of tear patterns in full-thickness rotator cuff tears and whether these patterns affect tendon healing after arthroscopic repair.
Clin Biomech (Bristol)
January 2025
Univ. Polytechnique Hauts-de-France, LAMIH, CNRS, UMR 8201, F-59313 Valenciennes, France.
Background: Multiple sclerosis induces locomotor impairments. The objective was to characterize the effects of Multiple Sclerosis on whole-body angular momentum control during gait initiation.
Methods: Fifteen patients with Multiple Sclerosis with Expanded Disability status scale of 2.
Bioinspir Biomim
January 2025
Chinese Academy of Agricultural Sciences, Chengdu 610213, PR China, Beijing, 100081, CHINA.
Among the components of a humanoid robot, a humanoid torso plays a vital role in supporting a humanoid robot to complete the desired motions. In this paper, a new LARMbot torso is developed for obtaining better working performance based on biological features. Through analyzing the anatomy of a human torso and human spine, a parallel cable-driven is proposed to actuate the whole mechanism by using two servo motors and two pulleys.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!