Universal decontamination of hospital surfaces in an occupied inpatient room with a continuous 405 nm light source.

J Hosp Infect

Burns Unit, Canniesburn Plastic Surgery Unit, Glasgow Royal Infirmary, Glasgow, UK.

Published: January 2018

Background: Previous work has shown that a ceiling-mounted, 405 nm high-intensity narrow-spectrum light environmental decontamination system (HINS-light EDS) reduces bacterial contamination of environmental surfaces in a burns unit by between 27% and 75%. Examination of the efficacy of the light over extended exposure times and its probable mode of action was performed.

Aim: To ascertain the correlation between bacterial kill achieved on sampled surface sites around the burns unit and both irradiance levels of the 405 nm light, and exposure time.

Methods: Seventy samples were taken using contact agar plates from surfaces within an occupied side-room in the burns unit before, during, and after a seven-day use of the HINS-light EDS. This was repeated in three separate studies. Statistical analysis determined whether there was significant decrease in environmental contamination during prolonged periods of HINS-light treatment, and whether there was an association between irradiance and bacterial kill.

Findings: A decrease of between 22% and 86% in the mean number of surface bacteria was shown during the use of the HINS-light EDS. When the light ceased to be used, increases of between 78% and 309% occurred. There was no correlation between bacterial kill and irradiance levels at each sampling site but strong correlation between bacterial kill and exposure time.

Conclusion: Prolonged exposure to the HINS-light EDS causes a cumulative decontamination of the surfaces within a burns unit. The importance of exposure time and possible airborne effect over irradiance levels is emphasized.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhin.2017.07.010DOI Listing

Publication Analysis

Top Keywords

hins-light eds
16
burns unit
16
correlation bacterial
12
bacterial kill
12
irradiance levels
12
surfaces occupied
8
405 nm light
8
surfaces burns
8
light
5
hins-light
5

Similar Publications

Universal decontamination of hospital surfaces in an occupied inpatient room with a continuous 405 nm light source.

J Hosp Infect

January 2018

Burns Unit, Canniesburn Plastic Surgery Unit, Glasgow Royal Infirmary, Glasgow, UK.

Background: Previous work has shown that a ceiling-mounted, 405 nm high-intensity narrow-spectrum light environmental decontamination system (HINS-light EDS) reduces bacterial contamination of environmental surfaces in a burns unit by between 27% and 75%. Examination of the efficacy of the light over extended exposure times and its probable mode of action was performed.

Aim: To ascertain the correlation between bacterial kill achieved on sampled surface sites around the burns unit and both irradiance levels of the 405 nm light, and exposure time.

View Article and Find Full Text PDF

Background: Although the germicidal properties of ultraviolet (UV) light have long been known, it is only comparatively recently that the antimicrobial properties of visible violet-blue 405 nm light have been discovered and used for environmental disinfection and infection control applications.

Aim: To review the antimicrobial properties of 405 nm light and to describe its application as an environmental decontamination technology with particular reference to disinfection of the hospital environment.

Methods: Extensive literature searches for relevant scientific papers and reports.

View Article and Find Full Text PDF

Infections are the leading cause of morbidity and mortality in burn patients and prevention of contamination from exogenous sources including the hospital environment is becoming increasingly emphasised. The High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS) is bactericidal yet safe for humans, allowing continuous disinfection of the environment surrounding burn patients. Environmental samples were collected from inpatient isolation rooms and the outpatient clinic in the burn unit, and comparisons were then made between the bacterial contamination levels observed with and without use of the HINS-light EDS.

View Article and Find Full Text PDF

Environmental decontamination of a hospital isolation room using high-intensity narrow-spectrum light.

J Hosp Infect

November 2010

Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), University of Strathclyde, Glasgow, UK.

The performance of a new decontamination technology, referred to as 'high-intensity narrow-spectrum light environmental decontamination system' (HINS-light EDS) was evaluated by a series of three studies carried out in a hospital isolation room used to treat burns patients. The ceiling-mounted HINS-light EDS emits high-intensity 405nm light which, although bactericidal, is harmless to patients and staff thereby permitting continuous environmental disinfection throughout the day. Performance efficacy was assessed by contact agar plate sampling and enumeration of staphylococcal bacteria on environmental surfaces within the room before, during and after HINS-light EDS treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!