The aim of this study was to evaluate the accuracy and feasibility of real-time 3-D echocardiography (3-DE) in assessing right ventricular (RV) systolic function. A latex balloon was inserted into the right ventricle of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. The RV global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and RV ejection fraction (RVEF), derived from 3-DE, as well as the RVEF obtained from 2-D echocardiography (2-DE) were quantified at different stroke volumes (30-70 mL) and compared with sonomicrometry data. In all comparisons, 3-D GLS, GCS, GAS, 2-D RVEF and 3-D RVEF exhibited strong correlations with sonomicrometry data (r = 0.89, 0.79, 0.74, 0.80, and 0.93, respectively; all p values < 0.001). Bland-Altman analyses revealed slight overestimations of echo-derived GLS, GCS, 2-DE RVEF and 3-DE RVEF compared with sonomicrometry values (bias = 1.55, 2.72, 3.59 and 2.21, respectively). Furthermore, there is better agreement among GLS, 3-D RVEF and the sonomicrometry values than between GCS and 2-D RVEF. Real-time 3-DE is more feasible and accurate for assessing RV function than 2-DE. GLS is a potential alternative parameter for quantifying RV systolic function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2017.05.007 | DOI Listing |
Trans R Soc Trop Med Hyg
December 2024
Infectious Diseases Unit, Department of Medicine, Sarawak General Hospital, 93586 Kuching, Sarawak, Malaysia.
Dengue is a vector-borne infection, which contributes to significant morbidity and mortality in endemic areas. It manifests rapidly within 2 wk from febrile, critical to recovery phase. The point-of-care test (POCT) comprises the non-structural protein 1 (NS1) antigen, IgM and IgG, which aids rapid diagnosis, leading to timely treatment.
View Article and Find Full Text PDFSensors (Basel)
November 2024
College of Geophysics and Petroleum Resources, Yangtze University, Wuhan 430100, China.
The flow dynamics of low-yield horizontal wells demonstrate considerable complexity and unpredictability, chiefly attributable to the structural attributes of the wellbore and the interplay of gas-water two-phase flow. In horizontal wellbores, precisely predicting flow patterns using conventional approaches is often problematic. Consequently, accurate monitoring and analysis of water holdup in gas-water two-phase flows are essential.
View Article and Find Full Text PDFCurr Dev Nutr
November 2024
Department of Chronic Diseases and Metabolism, Clinical and Experimental Endocrinology, KU Leuven, Leuven, Belgium.
Background: Most technology-based dietary assessment methods use the same methodology as traditional dietary assessment methods resulting in similar limitations and biases. Experience sampling methodology (ESM) is a real-life real-time data-capturing method that is explored as an alternative methodology for dietary assessment to improve feasibility and data accuracy.
Objectives: This research aimed to develop and evaluate an experience sampling-based dietary assessment method (ESDAM) measuring habitual dietary intake.
Sci Rep
November 2024
School of Electronic and Information Engineering, Guangdong Ocean University, Zhanjiang, 524088, China.
Dynamic LR and QR factorization are fundamental problems that exist widely in the control field. However, the existing solutions under noises are lack of convergence speed and anti-noise ability. To this end, this paper incorporates the advantages of Dynamic-Coefficient Type (DCT) and Integration-Enhance Type (IET) Zeroing Neural Dynamic (ZND), and proposes an Adaptive and Robust-Enhanced Neural Dynamic (AREND).
View Article and Find Full Text PDFAm J Physiol Lung Cell Mol Physiol
January 2025
Department of Physiology, Faculty of Medicine, School of Health Sciences, University of Thessaly, BIOPOLIS, Larissa, Greece.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!