AI Article Synopsis

  • The study compares a novel mechanical cup navigator with a conventional cup alignment guide in total hip arthroplasty (THA) to improve acetabular component orientation.
  • The research involved 136 hips, with one group using the conventional guide and the other using the new navigator, assessing the accuracy of cup placement based on postoperative angles.
  • Results showed that the mechanical navigator group achieved significantly better alignment and reduced discrepancies, suggesting it as an effective tool for enhancing accuracy in THA procedures.

Article Abstract

Background: The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide.

Methods: The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators.

Results: The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P < .0001). The discrepancies from the targeted angles were 3.5° ± 3.1° for the inclination angle and 4.6° ± 3.4° for the anteversion angle in the conventional group and 2.3° ± 2.3° and 3.2° ± 2.7°, respectively, in the mechanical navigator group (P = .020, P = .012).

Conclusion: The mechanical cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2017.06.033DOI Listing

Publication Analysis

Top Keywords

cup alignment
16
cup
13
cup navigator
12
conventional group
12
mechanical navigator
12
navigator group
12
cup angles
12
pelvic lateral
8
lateral positioner
8
mechanical cup
8

Similar Publications

The physiological, functional, and structural properties of proteins and their pathogenic variants can be summarized using many tools. The information relating to a single protein is often spread among different sources requiring different programs for access. It is not always easy to select, simultaneously visualize, and compare specific properties of different proteins.

View Article and Find Full Text PDF

Vacuum-assisted delivery (VAD) uses a vacuum cup on the fetal scalp to apply traction during uterine contractions, assisting complicated vaginal deliveries. Despite its widespread use, VAD presents a higher risk of neonatal morbidity compared to natural vaginal delivery and biomechanical evidence for safe VAD traction forces is still limited. The aim of this study is to develop and assess the feasibility of an experimental VAD testing setup, and investigate the impact of traction forces on fetal brain deformation.

View Article and Find Full Text PDF

Background: The combined anteversion theory is used for implant placement in total hip arthroplasty (THA). While majority of the research emphasizes the precise placement of the acetabular cup, there's less focus on stem alignment. This study aimed to investigate the impact of the discrepancy between the preoperatively planned femoral neck osteotomy level and the actual osteotomy level during surgery on stem alignment.

View Article and Find Full Text PDF

Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer.

Cureus

November 2024

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Article Synopsis
  • Portable navigation systems, like the NAVBIT which uses table tilt registration, can improve accuracy in cup alignment during total hip arthroplasty (THA).
  • A study with 96 patients compared the accuracy of THA using NAVBIT in the lateral position (with the flip technique) versus a cup goniometer in supine or lateral positions.
  • Results showed that the NAVBIT's alignment accuracy (average differences of 2.1° and 2.0°) was significantly better than the cup goniometer’s (average differences of 3.4° and 5.0°), with a higher percentage of cases within 5° of target angles.
View Article and Find Full Text PDF

Background: The association between coffee and pancreatic cancer risk has reported inconsistent results. Therefore, a Mendelian randomization (MR) study was undertaken to investigate the association between coffee and pancreatic cancer from a genetic perspective.

Methods: In East Asian and European populations, independent genetic variants strongly associated with coffee were chosen as instrumental variables (IVs) from relevant genome-wide association studies (GWASs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!